background image

4

SICHERHEITSVORKEHRUNGEN

assembly Instructions

Safety Warning

1. PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE ASSEMBLING YOUR GREENHOUSE. 

2.   Sharp edges and corners can cause injury. Always wear protective glasses, gloves, shoes and headgear when handling the aluminium profiles, glass and 

polycarbonate sheets. Broken glass is a safety hazard – always clear up immediately and dispose of with care.

3.  The product you have purchased is intended 

only

 for the growing of plants and should 

only

 be used for this purpose. When used for other purposes we 

will take no responsibility.

4. It is recommended that this greenhouse is assembled by two people.

5.  Should you encounter difficulties constructing this house, or in fitting the glass or polycarbonate sheets, please contact your retailer 

 

– do not use force!

6. The greenhouse must always be anchored.

011.02.1108

 SIte SelectIoN 

 

Always try to select a sunny location, sheltered 

from the wind as much as possible. 

  

 ImPoRtaNt 

 

Before assembling your new greenhouse, 

please check that all parts in the provided list 

are included. Please take each bundle out of 

the packaging in order to identify the parts 

better.
It is important that the opened bundles do not 

get mixed with one another.
If something is missing please contact your 

retailer.

 NeceSSaRy toolS 

 

Screw drivers (Normal and Crosshead PH2), 

10mm and 17mm spanner or wrench, 10 mm 

combination spanner, 1.8m Step ladder, Craft 

knife, Measuring stick, Spirit level, ø 20 drill, 

Accu-drill with adjustable torque.

 maINteNaNce 

 

The greenhouse should be thoroughly washed 

with a gentle detergent occasionally. Please 

check that the detergent used does not react 

aggressively with aluminium or plastic. 
Ensure that the door tracks are cleaned regu-

larly to avoid a build up of debris 

 0. BaSe 

 

Important! The base must be level. A zinc-

coated steel base is available as an accessory 

for all greenhouse models.  
(

Attention!

 Only when the greenhouse has to 

be located in a very windy and unprotected 

location: 

Drill through both the profile at the 

base of the greenhouse and the steel base, 

and connect them with nuts and bolts.)
If you would rather construct your own stone 

or concrete foundation, please follow the 

dimensions specified in diagram 0. 

Treated wooden beams at least 18mm high 

and not more then 32mm wide should be posi-

tioned between the stone/concrete foundation 

and the aluminium frame(A-A). On the side 

where the door will be located use a treated 

wooden beam not more then 52mm wide 

(B-B). Connect the wooden beams to the foun-

dation with 50mm long bolts (not provided). 

Foundations must extend down below the frost 

level.

Diagrams in a single frame show the view 

from inside the greenhouse. those enclo-

sed in a double frame show the view from 

outside the greenhouse. 

  

 

 1. SIDe elemeNtS 

 

 Lay all of the parts on the floor and connect 

them loosely. (1.1) to (1.6) 

Note:

 All bolt heads must slide into the bolt 

channels in each vertical bar. 

Repeat for the other 4 plain sides.

 2. SIDe elemeNt - DooR 

 

Lay all of the parts on the floor and connect 

them loosely, (2.1) to (2.6).

 3. coNNectINg the SIDe elemeNtS 

 

Bolt the six side elements together using 

corner plates (1092), (3.1) to (3.3). 

Carefully insert the plastic eave ends (6067) 

into the eaves at each corner, (3.4) to (3.6).

Now position your frame on the prepared base 

/ foundation and connect loosely. (Please only 

tighten these bolts after the building is glazed.) 

Adjust the frame until it is square and vertical 

and tighten the bolts connecting the sides. 

Please do not over tighten.

 

 4a. Roof 

 

 

Lay all roof bars (6087) on the ground and 

accurately mark them with a pencil as shown, 

(4.1). These marks are important to ensure the 

glazing panes fit later. 

Connect the assembly help disc (6098) to the 

hexagonal cone (6095) using bolt (3001) and 

nut (3002) (4.2). 

Assemble roof bars (6087) onto cone (6095) 

(4.3) (4.4). 

Note: 

the straight cut edge of (6087) should 

touch disc (6098) (4.3).

Tighten all bolts.

Connect ring beam (6097) with the joining 

point edge on the mark (1055 mm) (4.5) (4.6).

 4B. Roof 

Two people should now lift the assembly onto 

the roof. 

Connect roof bars (6087) onto each corner 

(4.7).  

Using the step ladder connect roof middle bars 

(6088) to hexagonal cone (6095) (4.8), ring 

beam (6097) (4.9) and eave angle (6072) / 

(6073) (4.10). Tighten all bolts.

Assemble the outer cone (6036) with bolt 

(6052), washer (6061), spacer (1010) and nut 

(3002) and lift into place. 

Note:

 

bolt (3001) and nut (3002) connecting 

disc (6098) must be removed at this point.

Inside connect bolt extension (6038) to bolt 

(6052) and then connect cover (6099) to 

(6038) using washer (6061) and bolt (6059) 

(4.11).  

 5l & R. DooRS 

 

Lay vertical door bars (6023) / (6085) on the 

ground and prepare 6 bolts (3001) in the bolt 

channels in each.

Press the glazing seals (1020) onto (6023) / 

(6085) (5.1) and cut to length.

Connect (6014) to bars (6023) / (6085) using 

the prepared end bolts and washers (6060) 

(5.2).

Position the top glass pane (A) and then 

middle bar (6015) or (6016) onto (6023) / 

(6085) (5.3). 

Finally position the lower glass pane (B) and 

connect (6017) using the last two prepared 

bolts (5.4).

Fix the glass on both sides with the plastic 

fixing strips (6031) (5.5).

Summary of Contents for Hera 2 9000

Page 1: ...011 02 1108 Hera 2 9000 Assembly instructions Montageanleitung Montagevejledning Monteringsanvisning D DK S...

Page 2: ...Quantity 9000 6005 2 1797 2 6007 2 951 2 6008 1 1151 10 6013 1 2 1797 12 6014 5L R 458 2 6015 5L 436 1 6016 5R 436 1 6017 5L R 436 2 6019 6 636 3 6020 6 803 3 6021 6 803 3 6022 1 2 1797 6 6023 5L R 17...

Page 3: ...5L R 6 12 24 6061 4B 6 17 2 6062 5L R 8 3 9 x 9 22 6066 6 610 3 6067 3 81 2 6 6068 7 3 5 x 13 18 6070 8 13 5 190 Item No Part Sect Ref Size mm Quantity 9000 6072 1 1854 5 6073 2 1854 1 6074 7 1854 6...

Page 4: ...ll be located use a treated wooden beam not more then 52mm wide B B Connect the wooden beams to the foun dation with 50mm long bolts not provided Foundations must extend down below the frost level Dia...

Page 5: ...g strips 6030 or 6032 onto each side 7 6 7 7 Now tighten the bolts connecting the building to the foundation 8 positioning of vents and doors Lift the vents into the prepared positions in the sides by...

Page 6: ...rofilen werden vorbehandelte witterungsbest ndige Holzleisten von mindestens 18 mm Dicke und max 32 mm Breite ben tigt die zwischen Aluminiumrahmen und Fundament montiert werden A A F r die T rseite e...

Page 7: ...rch eine Plastikfolie oder einen gedruckten Hinweis an den Kanten gekennzeich net Diese Seite muss nach au en zeigen Ent fernen Sie die Folie Die Scheiben D E und F in die vorgese henen F hrungsschien...

Page 8: ...har 5 identiske sider 2 side med d r Placer delene p jorden og bolt dem l st sammen se 2 1 til 2 6 I de lodrette sp r 6022 6013 6005 anbringes 1 ekstra bolt til at kunne fastg re tv rstiver 6004 og s...

Page 9: ...013 og 6022 se 7 5 og sk r gummilisten til i rette l ngde Monter glassene G H og J ved hj lp af monteringslisterne 6030 eller 6032 som vist i 7 6 og 7 7 Det anbefales at v re to personer til at foreta...

Page 10: ...ken och f st dem l st med bult och mutter Se 1 1 till 1 6 Kom ih g att f ra in extra bult i de lodr ta glasprofilerna 6022 6013 f r att senare kunna montera de v gr ta str vorna 6003 samt de diagonala...

Page 11: ...p av 6077 6078 och 6079 med skruv 7349 enligt 7 4 s att de ej glider ut F st takfotsf rst rkning 6074 p takfotspro filer 6072 6073 med j mna mellanrum med skruvar 6068 Se 7 6 7 7 r det sv rt att f dit...

Page 12: ...12 DIANA 0 011 02 1108 Hera 2 9000 30 x 20 mm 52 x 20 mm a a b b a a b b a a a a a a a a 3768 mm 3263 mm 22 mm 6001 6002 1884 mm 120...

Page 13: ...3 6072 6003 6001 6013 6008 6008 1092 6022 1 6 1 1 1 3 1 4 1 5 1 2 6072 6013 6013 6008 6003 6013 6001 6008 6022 6001 6003 6022 1 6 1092 6072 6022 6072 6013 1092 5x 1 3001 5x 12 3002 5x 12 6001 5x 1 600...

Page 14: ...14x 6002 1x 6004 2x 6005 2x 6007 2x 6013 2x 6022 1x 6073 1x 2 2 2 3 2 4 2 5 2 1 2 2 2 3 2 4 2 5 2 6 6005 6013 6002 6073 6004 6007 6007 6022 1092 6004 6005 6013 6004 6007 6005 6013 6002 6007 6022 6002...

Page 15: ...1 3 15 011 02 1108 Hera 2 9000 1092 6x 3001 24x 3002 24x 6067 6x 3 1 3 2 3 3 3 1 3 2 3 3 3 4 3 5 3 6 6022 6001 6008 6003 6022 1092 6072 6022 3 4 3 5 6067 6072 6072 3 6 6072 6067 6067 6072 6072...

Page 16: ...ra 2 9000 3001 25x 3002 25x 6087 6x 6095 1x 6097 6x 6098 1x 4 1 1055 mm x 6 6087 6087 6087 6097 6097 6097 6097 6097 6097 6095 4 3 4 4 4 5 4 6 4 2 6098 6095 3001 6087 6095 6098 6087 1055 mm 6097 6087 6...

Page 17: ...8x 3002 49x 6036 1x 6038 1x 6052 1x 6059 1x 6061 2x 6088 12x 6099 1x 4 8 4 10 4 10 4 7 6087 6 0 9 5 4 9 6088 4 10 4 7 4 9 4 8 4 11 1092 6022 6072 6073 6087 6088 6097 6088 6073 6005 6013 4 11 6052 6061...

Page 18: ...6051 4x 6055 1x 6057 2x 6060 12x 6062 2x 6085 1x 5 3 5 1 5 2 5 3 5 5 5 4 6023 6014 6017 6015 5 5 5L 6 6015 6060 3002 6050 6055 6031 5 6 5 2 1020 6057 6014 6062 3002 6060 6051 6049 6051 3002 6039 6046...

Page 19: ...6053 2x 6057 2x 6058 2x 6060 12x 6062 2x 5 2 5 1 5 5 5R 6 6016 6060 3002 6031 5 6 5 1 5 2 5 3 5 5 5 4 6014 6023 6016 6017 6040 6058 6042 6043 6044 6045 6048 6047 6053 6053 6041 6014 6062 5 3 6051 6049...

Page 20: ...3x 1 6024 3x 1 6025 3x 1 6034 3x 1 6066 3x 1 6 9 No 3 mm 9000 C 367 9591 750 x 610 3 Total 3 6 6 6 7 6 5 6 3 6 2 6 1 6019 6013 6019 6008 6003 6 8 3001 6 4 1003 6025 1003 6020 6024 6025 6021 6020 6 2 6...

Page 21: ...9701 1793 x 470 2 H 367 9681 982 x 610 3 J 367 9711 1793 x 610 12 Total 35 D D D E E E F E F F F G G H J J J 1020 6013 6022 1020 1020 6030 6030 6030 6030 6030 6030 6030 6030 6032 6032 6022 6030 6032...

Page 22: ...90x 6075 12x 6076 6x 7349 18x 8 1 8 2 8 3 8 4 8 5 8 6 8 7 8 7 8 6 8 2 8 1 8 8 8 4 C H 1019 6056 1067 6062 J C 6013 6066 6025 6066 8 3 6039 6002 6085 B 6002 6074 6057 A 1 2 8 8 8 11 6070 8 10 8 9 8 11...

Page 23: ......

Page 24: ...ostfach 170163 44060 Dortmund Deutschland Tel 49 231 941655 0 Fax 49 231 941655 99 www eph schmidt de verkauf eph schmidt de OPJ A S Volderslevvej 36 A Postboks 480 5260 Odense S Danmark Tel 45 66 15...

Reviews: