VitalConnect VistaPoint 3.2 Instructions For Use Manual Download Page 14

VistaTablet

14

IFU-26 Rev. J   |   December 2021

VistaPoint

Menu

PatientName Organization | DeviceName

Device ID: 50-50-a4-d9-d2-7a

Report Symptom

1s

2s

3s

4s

5s

Live ECG

2 mv

-2 mv

VitalPatch

VitalPatch ID b008bf_012792 has

   109 hours   

remaining

 

Posture

Upright

 

Fall Detection

No falls 

detected

Steps

Activity

463

BPM

Heart Rate

72

BrPM

Respiration Rate

14

From VitalPatch

Body Temp

98.6°F

%SPO2

Streaming Mode

97

Disconnect

Oxygen Saturation

00:0B:57:AC:66:DA

mmHg

Manual Entry

118 / 77

Last Reading:

2 Hours Ago

Take BP

Blood Pressure

No Device Paired

 

Manual Entry

61.7 kg

136.0 lbs

Take Weight

Last Reading:

2 Hours Ago

Weight

No Device Paired

Section 9: 

Using the VistaPoint Dashboard

VitalPatch ID

Main Menu

VitalPatch

Hours Remaining

Live ECG

(Optional. Not on 

VistaPhone.)

Device ID

Report a Symptom

Section 11 on pg 17

Patient Name, 

Device Name

 and Organization

Heart Rate

Respiration Rate

Body Temperature

Section 13 on pg 18

Section 15 on pg 19

Posture

Fall Detection

Activity (Steps)

Oxygen Saturation

See Section 16Section 22Section 26

 

Blood Pressure

See Section 17, Section 27

Weight

See Section 18, Section 28

VistaPhone with Simplified Display

Your VistaPhone device may be configured for a simplified 

display that does not show vital signs. For these devices, 

your vital signs continue to be collected and will be 

monitored remotely by your care team.

VitalPatch

Menu

92%

5:45 PM

Report Symptom

VitalPatch ID

012792

Vital Signs

Uploading

Body Contact

Good

Patient: PatientName24Chars
Org: OrganizationName

Device

Del-Boca-Vista-347

Cloud Connection

Good

Device ID

d27a

Data Storage

Good

Mobile Device

Hours

Remaining

109

VistaPhone with Vital Sign Display

Your VistaPhone device may display vital signs. See figure 

below. Note that the VistaPhone does not provide display 

of ECG data. 

Main Menu and 

Report Symptom

Main Menu

Patient Name

Organization

Vital Signs from 

VitalPatch

VitalPatch Hours 

Remaining

VitalPatch Hours 

Remaining

Oxygen 

Saturation

Report

Symptom

Weight
Patient Name

Device Name

Organization

Device ID

Blood 

Pressure

Device Name

Device ID

Menu

Device Paired

- -

Last Reading: None

A&D UA-651  00:01:0C:82:BF:6E

Blood Pressure

No Device Paired

- -

Last Reading: None

Weight

VitalPatch

Report Symptom

Device: DeviceName
Org: OrganizationName
Patient: PatientName
Device ID: ecb3
 

VitalPatch ID 0087ea has   94 hours   remaining.

5:45 PM

Take SPO2

Take BP

Take Weight

Streaming Mode

98%

Oxygen Saturation

 

Heart Rate

74 BPM

 

Respiration Rate

19 BrPM

 

Posture

Upright

 

Fall Detection

No falls

 

Activity

517 Steps

Body Temp

38.7°C

Calibrate Temp

Berry BM1000  00:01:0C:82:BF:6E

Summary of Contents for VistaPoint 3.2

Page 1: ...vision History 2 Getting Started Setting Up VistaTablet or VistaPhone Device 3 Checking Device Battery Level and Patch Hours 5 Changing Patient Name and Device Name 6 Removing Previous VitalPatch 7 Ap...

Page 2: ...ate spot check behavior streaming mode no longer supported for Nonin 3230 Rev E Added support VistaPoint Release 3 2 Changes include controls for modifying and displaying patient name and device name...

Page 3: ...itoring session unpack the VistaTablet or VistaPhone device Keep the packaging that was provided Locate the following VistaTablet or VistaPhone USB charger and charging cable VitalPatch biosensors and...

Page 4: ...d hold the Power Key until the Options menu displays and then select Power Off Unlocking the Device If the VistaTablet or VistaPhone device is asleep black screen unlock and start the VistaPoint appli...

Page 5: ...ovider as soon as possible Failure to return may result in additional charges for monitoring services The monitoring equipment includes the following VistaTablet or VistaPhone USB charger and charging...

Page 6: ...permission to change the patient name 3 Enter the new patient name in the space provided Allowed characters are letters numbers hyphens spaces periods and underscores No other characters are allowed...

Page 7: ...r of the overlay and peel it off the skin b Continue pulling the overlay off Stretch the overlay horizontally to help release it from the skin Note The VitalPatch may begin pulling off with the overla...

Page 8: ...inimum of 2 minutes before powering on the VitalPatch You may prepare the chest next step while waiting 2 Prepare Chest a If there is body hair on the site shave the site before cleaning Prepare an ar...

Page 9: ...omfort or irritation occurs the VitalPatch and the optional adhesive overlay should be removed Contact your healthcare provider immediately If the VitalPatch begins to fall off or lift from the skin c...

Page 10: ...erlay over the VitalPatch with the blue liners against the chest The raised portions of the VitalPatch should be aligned with the cutouts of the overlay See figure to the right b Ensure the tab you cr...

Page 11: ...complete the help sequence Tap the Bluetooth ID of your VitalPatch ID when it appears on the screen If VistaPoint asks how you want to connect choose one of the following options Tap Search for VitalP...

Page 12: ...g you to confirm your selection Note If you have a pacemaker VistaPoint will not display ECG heart rate or respiration rate If pacemaker status has been incorrectly selected it may be changed later Se...

Page 13: ...ed after performing or skipping the temperature calibration See Section 9 on page 14 for more information 8 Recalibrate Body Temperature If your configuration supports automatic body temperature you m...

Page 14: ...ed for a simplified display that does not show vital signs For these devices your vital signs continue to be collected and will be monitored remotely by your care team VitalPatch Menu 92 5 45 PM Repor...

Page 15: ...a VitalPatch that does not support automatic body temperature selecting this option will display a unit setting screen See Section 13 on page 18 Flash Patch LED Use to check pairing between VistaPoin...

Page 16: ...oaded automatically using approved Bluetooth devices Blood Oxygen Saturation as SpO2 Blood Pressure mmHg systolic and diastolic Weight pounds and kilograms Fall Detection If the VitalPatch detects a f...

Page 17: ...l not be applied turn off the VistaTablet or VistaPhone by pressing and holding the Power Key on until the Options menu displays and then select Power Off CALL 911 if you are experiencing an emergency...

Page 18: ...Measure temperature with a clinical grade thermometer 2 Tap the Menu button and then tap Calibrate Temperature or tap the Body Temperature tile on the dashboard 3 Tap the units Celsius C or Fahrenheit...

Page 19: ...manual entry Section 15 Entering Body Temperature Manually Your care team may direct you to enter an oxygen saturation SpO2 reading manually on a regular schedule for example one or more times per day...

Page 20: ...nter value and then re enter the value Section 17 Entering Blood Pressure Manually Tap Take BP or Take a Measurement Take Weight Manual Entry Use Bluetooth Weight value 206 6 Clear Values Enter Pounds...

Page 21: ...ssage continues The VitalPatch cannot be reapplied by pressing down to re adhere The VitalPatch partially or completely falls off the skin If the VitalPatch must be replaced select Disconnect Patch fr...

Page 22: ...ashboard will display a VitalPatch Not Detected message See Section 10 on page 17 for more information Message Posture Calibration Required If posture becomes Unknown VistaPoint will direct you to per...

Page 23: ...t indicates that the VistaTablet or VistaPhone does not have a wireless connection or that the cloud service is down See messages above for more information Checking Your Wireless Connection Your Vist...

Page 24: ...ing procedure 1 Plug VistaTablet into the charger If the battery is completely discharged the it may need several minutes to recharge before you can restart next step 2 Restart the VistaTablet by hold...

Page 25: ...is ON Check the Bluetooth indicator in the display The indicator will be displayed when Bluetooth is ON If it is not ON use a long button press to turn it ON To power off the device press and hold th...

Page 26: ...tion tile This will remove the pairing between VistaPoint and the Berry device Error Messages During Measurement The following error messages may be displayed in VistaPoint when taking a measurement S...

Page 27: ...on again to move between options Long press the ON OFF button to select an option or to change its value Ensure Bluetooth is ON using the menu To power off the device press and hold the ON OFF button...

Page 28: ...tion tile This will remove the pairing between VistaPoint and the Berry device Error Messages During Measurement The following error messages may be displayed in VistaPoint when taking a measurement S...

Page 29: ...the device Release the device to close The display should face up b Check the display of the unit See figure to the right If the Bluetooth icon is displayed in the upper right of the display no additi...

Page 30: ...he number under mac 3 Take a Reading in VistaPoint a Apply Masimo MightySat device to the finger The device will turn on and begin measuring See figure to the right b Tap Take SpO2 in the Oxygen Satur...

Page 31: ...e team Note Monitor battery life and replace batteries as necessary 1 Find the Bluetooth ID Optional Note This step is optional and is only necessary when using the Model 3150 in an environment where...

Page 32: ...finger h If the monitoring session is complete tap Disconnect in the Oxygen Saturation tile This will remove the pairing between VistaPoint and the Nonin 3150 Error Messages During Measurement The fo...

Page 33: ...to the right The Bluetooth ID begins with BDA 2 Pair New in VistaPoint a Tap Take SpO2 in the Oxygen Saturation tile Tap Use Bluetooth and then tap Pair New Tap Nonin Model 3230 as the model b Apply t...

Page 34: ...ading When the reading is complete the oxygen saturation will be displayed on the dashboard with an indicator of when the reading was taken If the oxygen saturation value is not displayed repeat the p...

Page 35: ...y when using the UA 651 in an environment where multiple similar devices are being used such as a hospital To find the Bluetooth ID turn the base unit over and find the label above the battery compart...

Page 36: ...on on the base unit to take a reading VistaPoint displays Please wait connecting while it retrieves the current reading When the reading is complete the blood pressure will be displayed on the dashboa...

Page 37: ...o confirm the device pairing tap Confirm 3 Take a Reading a Tap Take Weight in the Weight tile b Tap Use Bluetooth if not already selected c Tap Take Reading or Take a Measurement on VistaPhone and th...

Page 38: ...4 Airport Parkway Suite 300 San Jose CA 95110 408 963 4600 www vitalconnect com support vitalconnect com 2021 VitalConnect A list of our trademarks can be found at www vitalconnect com All other marks...

Reviews: