For example, to trigger on both port 1 and 2 being closed fill in trigger value 3
(1+2). To trigger on port 5 and 6, fill in value 48 (16+32).
A.7
GPO
Trigger Type
Trigger Value
Flank
Description
Channel
Port number
Change
Port state changes
Channel
Port number
Down
Port is closed
Channel
Port number
Up
Port is opened
Binary
Combination value
-
A combination of ports being closed
Use the Binary trigger type to catch port combinations. Specify the port com-
bination by adding the values that correspond to the ports (see table below).
This value is entered as the trigger value.
Port
Value
1
1
2
2
3
4
4
8
5
16
6
32
7
64
8
128
For example, to trigger on both port 1 and 2 being closed fill in trigger value 3
(1+2). To trigger on port 5 and 6, fill in value 48 (16+32).
A.8
UDP
Trigger Type
Trigger Value
Flank
Description
Message
String
-
Receive a message that matches the trigger-value
Receiving
-
-
Receive any message
The user can define his own string as the trigger value of a message. Please
note that this string has a maximum length of 25 characters.
It is possible to pass a parameter along with a message. In order to do
this use the syntax
trigger=value
. For example when the trigger type is set
to ’message’ and the trigger value is set to
intensity
then the transmitting
equipment can pass an intensity level by sending
intensity=255
, where 255
can be any number in the range [0,255].
44