Page | 6 

Mute Mode –  
For Normally Open Non-Momentary Switch 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn off power before changing 

connections and switches.   

DIP Switch Configuration 

 

      1 

2 3 4             

5     6 

7 8

 

       1

  2    3     4 

5          6

 7     8 

 

Application Example  

The VCX150 mute mode automatically reduces volume to barely audible. 

When a visitor lifts an exhibit audio handset that triggers a NO non-

momentary switch starting a player, the visitor can adjust the volume 

with push buttons on the display (or on the handset). If the visitor 

returns the handset to the control element before the program ends, 

volume will diminish to nearly mute until the program stops or another 

person triggers the switch resuming the program at mid-range level.    

 

Operating Mode 

VCX150 detects change of state of the continuous NO switch and starts 

VCX volume reset program. When switch closes, playback volume is set 

to barely audible. 

 

For NC non momentary switch  use 1+ 4+ 5+ 6 UP  

 

Volume adjustment is relative 

15 dB + or – from input level. 

Also compatible: 

SOUNDSTIKvcx with integrated 

NO non-momentary switch. 

Requires Hanger Mount. 

Summary of Contents for VCX-150

Page 1: ......

Page 2: ...Satisfies ADA and Section 508 compliance regulations for adjustable volume with auto reset Personalized volume helps people who are hard of hearing and provides a superior listening experience for everyone Notice to Users 2017 VISTA GROUP INTERNATIONAL INC VISTA GROUP INTERATIONAL INC PROVIDES NO WARRANTY WITH REGARD TO THIS MANUAL IN NO EVENT SHALL VISTA GROUP INTERNATIONAL INC BE LIABLE FOR ANY ...

Page 3: ...onal com Page 2 Table of Contents Getting Started Differentiators 1 Notice to users 1 Table of Contents 2 VCX 150 Overview Overview 3 Caution 3 Connections 4 Specifications 4 Included In Box 4 Operating Modes Start Switch Detect Mode 5 Mute Mode 6 Invert Input Mode 7 Switch Double Echo Mode 8 Headphone Detect Mode 9 Silence Detect Mode 10 Companion Devices The VCX 11 VCX Audio Control and Reset Sy...

Page 4: ...r UP DOWN push buttons for raising and lowering volume and a low power speaker or headphone jack The volume resets automatically to midrange by setting the VCX 150 to one of the modes below list Power off when making changes to dip switch settings and connectors Reapply when all connections are complete otherwise settings will not activate Cautions Always use shielded Line Level audio input Amplif...

Page 5: ...pply 5VDC Regulated 1 Amp Max Power 200 Milliamps Status Indicator Power LED Push Buttons Optional Dry Contact Normally Open Size 4 x 3 x 1 Material Aluminum Black Paint with White Silk Screen Included in Box 5VDC Regulated 1 amp power supply 3 5mm Remote Jack for Headphone Out Optional Connections 1 COM Common for volume push button inputs 2 UP Increase volume push button Normally Open 3 DOWN Dec...

Page 6: ...ram at mid range and adjust volume while listening but not annoy the next visitor by leaving the level too high or too low Pressing push button again during playback resets volume to mid range but does not affect program playback To interrupt advance or stop player use DPDT push button or set with external relay For lighted push button use COM START AUX Operating Mode VCX150 automatically detects ...

Page 7: ...set that triggers a NO non momentary switch starting a player the visitor can adjust the volume with push buttons on the display or on the handset If the visitor returns the handset to the control element before the program ends volume will diminish to nearly mute until the program stops or another person triggers the switch resuming the program at mid range level Operating Mode VCX150 detects cha...

Page 8: ...o use as needed depending upon the system s switch type The VCX150 uses this mode to make a NO continuous switch act like a common momentary push button and trigger the volume reset program While audio content plays user can adjust volume up or down Operating Mode VCX 150 inverts activated condition logic state of continuous start input switch NO or NC When switch returns to influence of external ...

Page 9: ...fting a SOUNDSTIKvcx NC from its Hanger Mount automatically starts the audio program at mid range volume Replacing the SOUNDSTIKvcx in the holder resets volume and stops or resets audio playback depending upon player set up Operating Mode The VCX150 inverts the activated condition of the NC switch generating the initial reset and then acts as output relay For automatic start interrupt controls the...

Page 10: ...rts his headphone into a remote jack Volume can be adjusted by push buttons on the display or on one of Vista Group s pre wired control plates VCX150 retains volume level while headphone is plugged in To simultaneously play audio via loudspeaker at headphone mid range level connect the loudspeaker directly to player Ask us about compatible small amps for loudspeakers when more volume is needed We ...

Page 11: ...tting allows a visitor to listen to multiple audio programs started by typical push buttons without having to adjust the volume to his preferred level with each new program For instance as long as the visitor is actively listening and pressing selections with less than 30 of delay the volume will remain as adjusted If 30 seconds of silence is detected the volume will reset Operating Mode VCX150 pl...

Page 12: ... reset system is designed to provide seamless disability access for kiosks and exhibits offering audio description for headphone playback This is a quick upgrade for a kiosk to provide audio description or used by visitors BYOD headphones Adjustable volume while listening Automatic reset headphone detect Detects stereo or mono headphones Custom control plates available call to discuss your applica...

Page 13: ...hase This warranty is offered to the first end user customer if purchased and used in the United States If the unit requires service return it to Vista Group and it will be repaired or replaced at our discretion Units out of warrant or damaged by improper use abuse or unauthorized service or repairs will be repaired at prevailing rates at the time In no event shall Vista Group be responsible for c...

Reviews: