29
Quantum Evolution installation and user manual
The detection area is divided 8x6 cells. By default all-cells are in active mode. Use
the arrow keys to move around the screen and the SELECT button to toggle between
active and disabled. Set the cells over the areas of interest to active state.
Post Motion
This sets the how long the recording lasts after motion is detected. The time can be
set between 30 ~ 240 sec
.
Motion Sensitivity
It has 3 settings of: High, Mid, Low, these are set dependant to site conditions.
Frame rates
The frame rates can be set individually per camera, the number of frames available is
dependant on the resolution set (within GLOBAL PARAMETERS) e.g. 720X288
allows 50ips across the cameras, and 360X288 allows 100ips across the cameras.
On the 8 and 16 channel units go the PAGE 1 and use “ ” arrow to move to access
further channels.
Recording Quality
Three levels of compression: High, Mid, Low.
Save and Exit
All the values set-up will be stored and screen will step back to higher-level menu.