Important note 

Warning

 

In  order  to  ensure  the  reliable  performance  of  the 
equipment and the safety of the user, please observe 
the  following  matters  during  the  process  of 
installation, use and maintenance: 

The matters needing attention of installation 

The  power  plug  shall  be  handled  for  easy 

disconnection, and the disconnect coupler on the front 
panel shall also be maintained for easy disconnection. 

The device must not be exposed to water droplets or 

splashes,  and  no  objects  filled  with  water,  such  as 
vases, should be placed on the device. 

Please  do  not  use  this  product  in  the  following 

places: the place of dust, soot and electric conductivity 
dust,  corrosive  gas,  combustible  gas;  the  place 
exposed to high temperature, condensation, wind and 
rain;  the  occasion  of  vibration  and  impact.  Electric 
shock, fire, wrong operation can lead to damage and 
deterioration to the product, either.   

When processing screw holes and wiring, do not let 

metal  chips  and  wire  ends  fall  into  the  ventilation 
holes of the controller, which may cause a fire, fault 
and incorrect operation. 

When  the  installation  work  is  over,  it  should  be 

assured  there  is  nothing  on  the  ventilated  face, 
including packaging items like dust paper. Otherwise 
this may cause a fire, fault, incorrect operation for the 
cooling is not free. 

Should  avoid  wiring  and  inserting  cable  plug  in 

charged state, otherwise it is easy to cause the shock, 
or electrical damage. 

The  installation  and  wiring  should  be  strong  and 

reliable, contact undesirable may lead to false action;   

  For  a  serious  interference  in  applications,  should 

choose shield cable as the high frequency signal input 
or  output  cable,  so  as  to  improve  the  anti-jamming 
ability of the system.   

Attention in the wiring 

The equipment shall be connected to the grid power 

output socket with protective grounding connection. 

Only after  cutting  down  all external power  source, 

can  install,  wiring  operation  begin,  or  it  may  cause 

electric shock or equipment damage. 

This  product  grounds  by  the  grounding  wires.  To 

avoid  electric  shocks,  grounding  wires  and  the  earth 
must  be  linked  together.  Before  the  connection  of 
input or output terminal, please make sure this product 
is correctly grounded. 

Immediately remove all other things after the wiring 

installation. Please cover the terminals of the products 
cover  before  electrification  so  as  to  avoid  cause 
electric shock. 

Matters  needing  attention  during  operation  and 

maintenance 

Please do not touch terminals in a current state, or it 

may cause a shock, incorrect operation. 

Please do cleaning and terminal tighten work after 

turning  off  the  power  supply.  These  operations  can 
lead to electric shock in a current state. 

Please do the connection or dismantle work of the 

communication  signal  cable,  the  expansion  module 
cable or control unit cable after turning off the power 
supply,  or  it  may  cause  damage  to  the  equipment, 
incorrect operation. 

  Please  do  not  dismantle  the  equipment,  avoid 

damaging the internal electrical component. 

Should  be  sure  to  read  the  manual,  fully  confirm 

the  safety,  only  after  that  can  do  program  changes, 

commissioning, start and stop operation. 

 The button battery must be replaced during a power 

outage.  It  is  indeed  necessary  to  replace  it  with 
electricity due to the consideration of the operation of 
the  equipment,  and  it  needs  to  be  carried  out  by 
professional  electrical  technicians  wearing  insulating 
gloves.   

Matters needing attention in discarding product 

Electrolytic  explosion:  the  burning  of  electrolytic 

capacitor on circuit boards may lead to explosion. 

Please  collect  and  process  according  to  the 

classification, do not put into life garbage. 

Please  process  it  as  industrial  waste,  or  according 

to the local environmental protection regulations.

Summary of Contents for VIS-CATC-B

Page 1: ...www vissonic com VISSONIC ELECTRONICS LIMITED 1 VIS CATC B Camera Auto tracking controller User Manual V2 1 Version VISSONIC ELECTRONICS LIMITED ...

Page 2: ...gerous voltage without insulation occurring within the equipment may cause people suffer from shock CE certification means that the product has reached the directive safety requirements defined by the European Union Users can be assured about the use of it SGS certification means that the product has reached the quality inspection standards proposed by the world s largest SGS This product passed t...

Page 3: ...shall be connected to the grid power output socket with protective grounding connection Only after cutting down all external power source can install wiring operation begin or it may cause electric shock or equipment damage This product grounds by the grounding wires To avoid electric shocks grounding wires and the earth must be linked together Before the connection of input or output terminal ple...

Page 4: ...www vissonic cn VISSONIC ELECTRONICS LIMITED 4 Version Version Update Date 1 0 Publish 2018 12 28 2 0 Update interfaces and functions 2021 12 07 2 1 Update screen split function 2022 05 07 ...

Page 5: ...nt and rear panel function description 7 4 Installation 8 4 1 19 inch installation cabinet 8 5 Connection 9 5 1 Power supply 9 5 2 RS 232 control interface 9 6 Web Control 11 7 System connection diagram 14 7 1 Camera RS232 cascade control line connection method 14 7 2 Full Digital Network DSP Conference Controller CAMERA Menu Camera Tracking Settings 15 ...

Page 6: ...gital audio input b Video input port 2 channel HDMI HD interface HDMI supports 1080P60Hz downward compatibility supports digital audio input c Video input port 1 channel RCA audio interface analog audio d Video output port 2 channel HDMI HD interface HDMI supports 1080P60Hz downward compatibility supports up to four screen splits output supports audio output e Video output port 1 channel USB inter...

Page 7: ...3 5kg n Power consumption 8W 3 VIS CATC B camera tracking seamless switching controller front and rear panel function description Figure 3 1 VIS CATC B the front and rear panels The front panel of camera tracking includes 1 Power switch turn the power of the camera tracking controller on or off 2 Control button 1 6 button corresponds to 1 6 HDMI and SDI input channels can switch any 1 HDMI or SDI ...

Page 8: ...to connect the full digital network DSP conference controller for video switching control of camera tracking or connect the computer for control 8 Power input port connect the camera tracking controller to the power sequencer or plug in with the power cable to supply power to the camera tracking controller HDMI and SDI input interface supports digital audio input HDMI and USB output interface supp...

Page 9: ...ce Figure 5 2 1 RS232 female It is used to connect the digital network DSP conference main unit for video switching control of camera tracking or connect the computer for control Pin Signal Description Pin Signal Description 1 Null 6 Null 2 TXD Send data 7 Null 3 RXD Receive data 8 Null 4 Null 9 Null Warning The controller power supply needs to be well grounded to avoid causing fatal accidents ...

Page 10: ...nd Serial port default settings Baud rate 9600bps Parity 8 Stop 1 Serial control command table Instruction Function Return Information Remark x V y x input to y output video switching V x y Splice_mode x Multiple image mode selection Splice_mode x x 0 11 Audio_chn x Audio channel selection Audio_chn x FREEZE x Set the screen freeze time to x seconds FREEZE x x Unit second SetFreeze Perform screen ...

Page 11: ...x2 x3 x4 SUBR x1 x2 x3 x4 Set subnet mask SUBR x1 x2 x3 x 4 SHAR x1 x2 x3 x4 x5 x6 Set hardware address hex SHAR x1 x2 x3 x 4 x5 x6 NETDEFAULT Network restore factory settings 6 Web Control Network port default settings IP 192 168 1 189 1 Connect your PC to the Ethernet port of the camera tracking controller via a CAT5 cable 2 Please set your computer to the following IP range ...

Page 12: ...9 and if you can log in to the interface as shown in Figure 6 2 it means that the connection is successful Click Video and Audio to control the screen segmentation and audio switching of the camera tracking controller Screen split as shown below 1 2 3 Figure 6 2 Screen split 1 Signal list the video input signal of the camera controller ...

Page 13: ... Display window After selecting the desired multi image mode you can drag and drop various video signals directly on the display window Audio switching as shown below 1 4 Figure 6 3 Audio switch 4 Audio switching 1 channel analog audio and 6 channel digital audio input can be switched to output arbitrarily ...

Page 14: ...ww vissonic cn VISSONIC ELECTRONICS LIMITED 14 7 System connection diagram 7 1 Camera RS232 cascade control line connection method PIN1 DTR PIN2 DSR PIN3 TXD PIN4 GND PIN5 RXD PIN6 GND PIN7 IROUT PIN8 NC ...

Page 15: ...255 Off 001 to 255 Off 001 to 255 Camera select select the camera to setup there totally support 16 cameras Camera addr set the camera address for the camera selected on submenu Camera select SAMSUNG and PELCO D protocols need to set the address and VISCA protocol is set to off Video channel Bind the camera which set on submenu camera select to the video channel number of video switcher There are ...

Page 16: ...mera Step 8 Repeat the step 2 step 6 to finish the camera 02 More camera are set as the same way Step 9 After setting the last microphone on and off the MIC we can adjust the camera to give a full view of the meeting and press ESC to quit from the menu of Start Set The preset of full view will be active while there are no microphone on Example Here we have to set up two cameras using the VISCA SAM...

Page 17: ...CONTROL is connected with the RS232 port of the camera tracking controller VIS CATC B Step 3 Use the front panel of the conference processor and the camera remote control keyboard or CLEACON software to set the camera tracking preset position and input the camera information according to the following steps ...

Page 18: ...www vissonic cn VISSONIC ELECTRONICS LIMITED 18 ...

Reviews: