background image

5

Kado 25

1

2

3

4

1/2019 (US)

Weight loads

Wall frame and structures fixed to ceiling

 The fixtures must be selected according to the manufacturer‘s recommendations and the type of on-site masonry, and if necessary the 

substructure, must be able to support a tensile force of 264.6 lbs and a radial force of 88.185 lbs per upright.

1. Assemble horizontal frame on a flat surface. Ø 

7 mm

/0.276" holes in the connectors face inwards

2. Upright connectors to be inserted at 45° between the frames (up to the buffers) and then turned 45° using the assembly tool. The slots for acces-

sories face inwards.

3. Use Ø 

5 mm

/0.197" drill to drill through hole in connector

4. Use hammer to insert grooved locking pin into drill hole.

 All vertical connectors in units fixed to the ceiling must be pinned. 

 The indicated weight loads are always based on the total weights of the merchandise support and goods. 

Please also observe the weight loads indicated in our sales documentation.

Max. load

per castor Ø 

50 mm

/1.969"

88 lbs

per castor Ø 

75 mm

/2.953"

165 lbs

per glide Ø 

50 mm

/1.969"

132 lbs

Glass/wooden shelf

55 lbs

Reviews: