background image

D-303728 V-MOTION MCW, V-PET MCW 

V-MOTION MCW, V-PET MCW

 

 

 

English 

Wireless, PowerCode Digital PIR / Pet Immune PIR Detectors - 
Installation Instructions 

 

Fig. 1 - V-motion MCW / V-Pet MCW 

 

 

Español 

Detectores PIR Digital / Inmune a mascotas inalámbricos – 
Instrucciones de instalación 

 

 

Portuguese 

Detector PIR Digital / Imune a Animais Via rádio – Instruções 
de Instalação 

  

ENGLISH 

1. INTRODUCTION 

The 

V-motion MCW

 and 

V-Pet MCW

 (pet immune) are microprocessor-

controlled wireless digital PIR detectors.  

The detectors features are as follows: 

 Cylindrical lens with uniform detection sensitivity throughout its 

operating range, up to 12 meters (40 ft).  

  V-motion MCW includes wall creep zone protection. 

 In 

V-Pet MCW

, Target Specific Imaging™ (TSI)

 

technology is used for 

distinction between human beings and pets weighing up 

to 27 kg 

(60lb). 

  Incorporates a fully supervised PowerCode transmitter. 

 The advanced 

True Motion Recognition™ 

algorithm (patented) allows 

distinguishing between the true motion of an intruder and any other 

disturbances which may cause false alarms. 

  Sophisticated frequency domain digital signal processing. 

  No vertical adjustment is needed. 

 An on-board motion event jumper determines whether 1 or 2 

consecutive motion events trigger an alarm. 

  After detection, the detector disarms itself to save battery power. It 

rearms (reverts to the ready state) if there is no subsequent detection 

throughout the following 2-minute period. 

  An optional version provides better protection for systems compliant 

with DD243. After initial detection, the detector is capable of 6 

additional detections for a period of 5 minutes.  

Further detection is possible only if no movement occurs during the 

following 2 minutes. The detector will revert to the initial state if there is 

no movement for an additional 5 minutes. 

  Very low current consumption. 

  Microprocessor-controlled temperature compensation. 

  Sealed chamber protects the optical system. 

  Front and back tamper protection 

  White light protection. 

  Elegantly styled, sturdy case. 

For UL installations:

 The detector is for use with UL listed control unit 

P only. Pet immunity has not been evaluated by UL. 

2. SPECIFICATIONS 

Detector Type: 

Dual element low-noise pyroelectric sensor.

 

OPTICAL

 (see Fig. 2)

 

Lens Data

 

  No. of curtains:

 

V-motion MCW:

 46, equivalent to 214 beams. 

V-Pet MCW:

 36, equivalent to 196 beams. 

 Max. 

Coverage: 

12 x 12 m,   (40 x 40 ft) / 90° 

Pet Immunity (V-Pet MCW Only):

 Up to 27 kg (60 lb). 

ELECTRICAL 

Internal Battery:

 3V Lithium battery, type CR-123A. For UL installations, 

use Panasonic, Sanyo and GP only. 

Nominal Battery Capacity:

 1450 mA/h. 

Battery Life (with LED on): 

Typically over 3 years. 

Battery Power Test: 

Performed immediately upon battery insertion and 

periodically after every several hours.

 

FUNCTIONAL 

True Motion Event Verification:

 2 position selector - 1 (OFF) or 2 (ON) 

motion events. 

Alarm Period:

 3 seconds. 

Visual Indications:  

LED Lights 

for about 3 seconds upon transmission of alarm & tamper 

messages and upon motion detection in the walk test mode.  

LED Flashes

 during the power-up stabilization period, or after 

restoring (pressing) the tamper switch. 

LED Does not light 

upon transmission of supervision messages.  

Rearm Timer:

 Rearms the detector 2 minutes after the last alarm. Timer 

disabled in the walk test mode – not applicable for the DD243 version 

(see section 1). 

WIRELESS 

Frequency (MHz): 

315 (U.S. version), 433.92, 868.95 or other frequency 

according to local requirements. 

Encoding:

 24-bit ID, over 16 million possible combinations. 

Total Message Length:

 36 bits. 

Tamper Alert:

 Reported when a tamper event occurs and in any 

subsequent message, until the tamper switch is restored. 

Supervision Message: 

Signaling at 60 minutes interval (U.S. version), 15 

minute interval (UK version) or according to local standards. 

MOUNTING

  

Height:

 1.8 - 2.4 m (6 - 8 ft). For V-Pet MCW, the recommended height is 

up to 2.1 m (7 ft) 

Installation Options:

 Surface or corner. 

ACCESSORIES:  

BR-1:

 Surface mounted swivel bracket, adjustable 30° down and 45° 

left/45° right.  

BR-2:

 BR-1 with a corner adapter  

BR-3:

 BR-1 with a ceiling adapter 

ENVIRONMENTAL

 

RFI Protection: 

>20 V/m up to 2000 MHz. 

Operating Temperatures:

 -10

°C to 50°C (14°F to 122°F). 

Storage Temperatures:

 -20

°C to 60°C (-4°F to 140°F). 

Compliance with Standards:

 Designed to meet: 

USA

: FCC Part 15  

Europe

: Directive 1999/5/EC of the European Parliament.  

EN 50131-1 Grade 2 (detector with back tamper switch) /  

Grade 1 (detector without back tamper switch), Class II.;  

EN-50131-2-2 

PHYSICAL 

Size (H x W x D):

 94.5 x 63.5 x 53.0 mm (3-11/16 x 2-1/2 x 2-1/16”). 

Weight (with battery):

 70 g (2.5 oz). 

Color:

 White. 

PATENTS: 

U.S. Patents 5,693,943 

 6,211,522 

 D445,709 (another 

patent pending). 

3. INSTALLATION 

3.1 General Guidance

 

(see fig. 3) 

1. Keep away from heat sources. 

2. Do not expose to air drafts. 

3. Do not install outdoors. 

4. Avoid direct sunshine.

5. Keep wiring away from power 

cables. 

6. Do not install behind partitions. 

7. Mount on solid stable surface.

3.2 Installation Procedure 

1. Mounting - see fig. 4. 

2. Battery installation (see fig. 4) 

3. Detector reset: 

With the battery in place, press the tamper switch (see fig. 4) and 

release. The front LED will flash for about 2 minutes until the detector 

stabilizes.  

Note:

 The detector transmits a low battery signal upon detection of 

low voltage. It is recommended to wait about 1 minute after battery 

removal, before inserting the new battery. 

4. Enrolling: 

Enroll the detector's ID into the alarm system memory according to the 

alarm system installation instructions. When you are instructed to 

transmit, press tamper switch again and release. You may enroll the 

detector's ID while the detector's LED flashes. 

5. Jumpers settings - see fig. 4. 

6. Walk-test the coverage area - see fig. 2. Walk across the far end of 

coverage pattern in both directions. The LED should light for 2-3 

seconds each time your motion is detected. 

Important!

 Instruct the user to walk test at least once a week to verify 

proper function of the detector. 