panel
Z14.LOCATION
Z14.ZONE TYPE
Z14.SET CHIME
ð
Z14.PARTITIONS
ð
Z14:P1
n
--
P2 ....P3
n
ð
means scroll
ww
and select
OK
.
Notes:
[1] If the detector is already enrolled you can configure the detector parameters and assign partitions via the
“Modify Devices”
option – see Step 2.
[2] PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further details, see
"Partitioning" in the PowerMaster Installer Guide).
2.4. Configuring the Detector Parameters
Enter the
DEVICE SETTINGS
menu and follow the configuration instructions for the TOWER 20 AM PG2 PIR detector as described below.
Option
Configuration Instructions
ALARM LED
Define whether or not to activate the alarm LED indication.
Optional settings: ON (default) and OFF.
PIR
SENSITIVITY
Define if the detector operates at regular or high PIR sensitivity, or that at least one detection zone must be crossed before an alarm
is triggered (One Region).
Optional settings: LOW (default), HIGH and One Region.
Note:
For EN compliance, the detector should be set to "One Region".
DISARM
ACTIVITY
Define whether or not to set the activity time during Disarm mode.
Optional settings: NOT Active (default), YES – no delay, YES + 5s delay, YES + 15s delay, YES + 30s delay, YES + 1m delay, YES +
2m delay, YES + 5m delay, YES + 10m delay, YES + 20m delay and YES + 60m delay.
OUTDOOR
ANTI-M
Enable or disable the outdoor anti-masking feature.
Optional settings: Disabled (default) and Enabled.
ALARM
Hours
Define whether motion alarms are always enabled or only when dark (at night).
Optional settings: Day and Night (default) and Night only.
2.5. Local Diagnostic Test
A.
Set the detector in local diagnostic mode, as follows:
Open the detector’s bottom cover (see "Figure 4 – Battery Insertion" on the previous page , steps 1 - 3) and then press and release the tamper
switch (see "Figure 5. TOWER 20 AM PG2 " on the next page). The LED will flash for 60 seconds and then the detector will enter into 15 minutes'
local diagnostic mode.
Note:
Note: The detector automatically enters into 15 minutes' local diagnostic mode after battery installation or Tamper switch recovery.
B.
Adjust the detector in the horizontal plane to cover the required protected area.
C.
Walk into the detectors’ field of view. Adjust the vertical plane to receive the maximum number of detections when crossing the entire 90
°
pattern.
Verify that the LED blinks each time your motion is detected, as you cross one Quad PIR. Then verify that the LED lights steadily for 2 seconds as
you cross the next adjacent Quad PIR. After alarm indication, the LED blinks three times and provides the received signal strength indication (see
Table 2).
Table 2 – Received Signal Strength Indication
LED response
Reception
Green LED links
Strong
Orange LED blinks
Good
Red LED blinks
Poor
No blinks
No communication
Important!
Reliable reception must be assured. Therefore, "poor" signal strength is not acceptable. If you receive a "poor" signal from the detector, re-
locate it and re-test until a "Good" or "Strong" signal strength is received.
Note:
For detailed Diagnostics Test instructions refer to the control panel Installer's Guide
The LED blinking, described above, is operative only in Local diagnostic mode. Upon each full detection (LED lights steadily for 2 seconds), the control
panel receives the alarm. If required, perform the detector's horizontal / vertical adjustments (see section 2.1 and Figure 3).
Important!
Instruct the user to perform a walk test at least once a week, to verify proper operation of the detector.
D.
Place a piece of cardboard on the detector’s front side to deliberately mask the optical window. Verify that after 2 minutes, the yellow LED lights
continuously (see Table 3 below) and the alarm control panel receives the masking alarm.
E.
Remove the masking from the detector’s front side. Verify that the LED turns off
Table 3 - LED operation
LED Indications
Event
Red LED blinks
Stabilization (warm-up 60 sec)
Red LED ON 0.2 sec.
Tamper open / close
Red LED blinks twice
One quad PIR detection in diagnostic mode
Red LED on 2 sec.
Intruder alarm
D-304046 TOWER-20 PG2 Installation Instructions