Visonic TOWER-20 PG2 Installation Instructions Manual Download Page 1

D-304046 TOWER-20 PG2 Installation Instructions

1

1. INTRODUCTION

The TOWER 20 AM PG2 is a 2-way, wireless outdoor digital mirror PIR detector which includes the following features:

l

Patented 8 independent quad PIR detectors (Octa-QUAD

TM

) operating in true Quad configuration (patented) with true motion recognition (TMR)

processing for each of the 8 PIR detectors, as well as central motion processing that distinguishes between moving intruders and trees and bushes
in motion.

l

Advanced Obsidian Black Mirror

TM

optics (patent pending).

l

Optimum performance even in poor weather conditions such as snow, rain, dust, wind and direct sunlight

l

Tamper protection prevents opening and removal from wall

l

PowerG two-way Frequency Hopping Spread Spectrum

FHSS-TDMA technology

- provides robustness and reliability that is closer than ever to

wired systems

l

Built-in link quality indicators enable installer to check signal quality without physically approaching the control
panel, thus making installation faster and easier.

l

Robust housing with recessed window.

l

Smart anti masking distinguishes between masking spray and rain.

l

Alarm LED is visible in sunlight.

l

Automatic termination of walk-test after 15 minutes.

l

Microprocessor-controlled temperature compensation.

l

Immunity to pets weighing up to 18 Kg (40lb), not pet alley – see Table 1

l

Built-in swivel bracket

Figure 1.

General View

2. INSTALLATION

2.1. Installation

A.

Bracket installation (see Figure 2). Fix the bracket firmly on a stable wall or pillar. The orientation of the fixed bracket must be as parallel as possible
to the surveyed ground surface.

B.

Adjust the detector's horizontal and vertical angles (see Figure 3), according to the surveyed ground surface. The vertical angle indicator position
for various installation height and coverage distance combinations is detailed in Table 1 (the information refers to a relatively flat surveyed area.
Verify the correct installation by walk-test).

C.

Fasten the detector to the bracket (see Figure 2 step 4).

Table 1 - Vertical Adjustment Reference

Mounting Height

Coverage Distance

2m / 6.7ft

4m / 13ft

6m / 20ft

8m / 26ft

10m / 33 ft

12m / 39 ft

3.0m / 10 ft

-

1

2

2

3

3

2.5m / 8 ft

1

1

2

3

4

4

2.0m / 7 ft

1

2

3

4

5

5

1.5m / 5 ft

2

3

4

5

5

-

Note:

The grayed-in cells in Table 1 are the installation alternatives recommended for further reducing false alarms from pets.

TOWER-20 PG2

PowerG, Outdoor Mirror PIR Motion Detector with Anti-masking and Built-In
Camera

Installation Instructions

Summary of Contents for TOWER-20 PG2

Page 1: ...is visible in sunlight l Automatic termination of walk test after 15 minutes l Microprocessor controlled temperature compensation l Immunity to pets weighing up to 18 Kg 40lb not pet alley see Table...

Page 2: ...sten Note The 2 screw holes enable adjustment of the bracket on the wall if needed following the walk test E Three long screws F Two short screws Figure 2 Installation HORIZONTAL ADJUSTMENT 45 to 45 V...

Page 3: ...r to the PowerMaster control panel s Installer Guide and follow the procedure under the 02 ZONES DEVICES option of the Installer Menu A general description of the procedure is provided in the followin...

Page 4: ...iagnostic mode Note Note The detector automatically enters into 15 minutes local diagnostic mode after battery installation or Tamper switch recovery B Adjust the detector in the horizontal plane to c...

Page 5: ...measures Re orient or re locate the receiving antenna Increase the distance between the device and the receiver Connect the device to an outlet on a circuit different from the one that supplies power...

Page 6: ...Mounting Type Wall mounting Mounting Height 1 5 3 0 m 5 10 ft Horizontal Adjustment 45 to 45 in 5 steps Vertical Adjustment 0 to 10 in 2 5 steps ENVIRONMENTAL Operating Temperatures 35 C to 60 C 31 F...

Page 7: ...TY OF SUCH DAMAGE THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH PERSONAL AND OR BODILY INJURY AND OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHER...

Page 8: ...is supplied shall not apply Governing Law This disclaimer of warranties and limited warranty are governed by the domestic laws of Israel Warning The user must follow the Manufacturer s installation an...

Reviews: