Visonic SR-720B PG2 Installation Instructions Download Page 3

 

D-305640 SR-720B PG2 Installation Instructions 

3

 

4

4

4

4. 

. CONFIGURING THE SIREN PARAMETERS

CONFIGURING THE SIREN PARAMETERS

CONFIGURING THE SIREN PARAMETERS

CONFIGURING THE SIREN PARAMETERS    

Enter the 

DEV SETTINGS

 

menu and follow the configuration instructions for the SR-720B PG2 indoor siren as described below. 

Option 

Configuration Instructions 

STROBE ALARM 

Define whether or not to activate the strobe alarm, and if activated, whether to activate the strobe until the alarm 
system is disarmed, or, for the programmed period of time (see the "Siren Configuration" section in the control 
panel Installer Guide). 

Optional settings: 

Timer limited

 (default), 

Disabled

 and 

Until Disarmed

 

 

 

 

EXIT-ENTRY Beeps 

Define whether or not to activate the exit – entry beeps, and if activated, whether to activate in HOME or AWAY mode. 

Optional settings: 

Disabled

 (default), 

Disabled & Home

 and 

Enabled

 

 

 

 

SQUAWK

 

Define whether or not to enable the squawk, and if enabled, whether to activate the sounder only, or, the sounder and 
strobe simultaneously.

 

 

Optional settings: 

Disabled

 (default), 

Sounder only

Strobe only

 and 

strobe

.

 

 

 

 

 

SOUNDER VOLUME 

 

Define the volume level of the sounder. 

Optional settings: 

Volume HIGH

(default), 

Volume LOW

 and 

Volume MID

 

 

 

 

AUTO TAMPER ALRM 

Define whether or not the siren alone will sound a tamper alarm when there is no communication between the siren 
and the control panel. 

Optional settings: 

Disabled

 (default) and 

Enabled

 

 

 

 

 

5

5

5

5. 

. LOCAL DIAGNOSTICS TEST

LOCAL DIAGNOSTICS TEST

LOCAL DIAGNOSTICS TEST

LOCAL DIAGNOSTICS TEST    

Before  testing,  remove  the  plastic  cover  and  then  open  the 
battery cover (see Fig. 2). 

A.

  Press the self-test button (see Fig. 3) once and release it; the 

following procedure should occur in turn: 
The red LED will switch ON and then OFF, the green LED will 
switch ON and then OFF, the strobe light will switch ON and 
then  OFF  and  the  piezo  siren  will  sound  to  indicate  that  the 
siren is now fully operational.

 

B. 

After 2 seconds the LED blinks 3 times. 

The  following  table  indicates  received  signal  strength 
indication. 

 

 

LED response 

Reception  

Green LED blinks 

Strong  

Orange LED blinks 

Good  

Red LED blinks 

Poor  

No blinks 

No communication 

IMPORTANT!

  Reliable  reception  must  be  assured.  Therefore, 

"poor"  signal  strength  is  not  acceptable.  If  you  receive  a  "poor" 
signal  from  the  device,  re-locate  it  and  re-test  until  a  "good"  or 
"strong" signal strength is received.

 

For  detailed  Diagnostics  Test  instructions  refer  to  the  control 
panel Installer Guide. 

Note:

 For UL/CUL installations, the test result must be “Strong”. 

 

6

6

6

6. 

. COMPLIANCE WITH STANDARDS

COMPLIANCE WITH STANDARDS

COMPLIANCE WITH STANDARDS

COMPLIANCE WITH STANDARDS    

Compliance with Standards 

  

  

Europe: 

EN 301489, EN 50130-4, EN 50130-5, EN 50131-4 Type W, EN 300 220, EN 60950-1 

Security Grade 2, Environmental Class II. 

UK:

 This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and 

environmental class 2. DD243 and BS8243 
The  SR-720B  PG2  is  compatible  with  the  RTTE  requirements  -  Directive  1999/5/EC  of  the  European 
Parliament and of the Council of 9 March 1999. 

USA:

 CFR 47 Part 15 (FCC) 

Canada:

 RSS 210 

Certified by Applica T&C. 

The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in 
the  technical  brochure.  This  functionality  has  not  been  tested  to  comply  with  the  respective  technical  requirements  and 
should therefore be considered outside the scope of the product’s certification.

 

The digital circuit of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the 
FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in  residential  installations.  This 
equipment  generates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the  instructions, 
may  cause  harmful  interference  to  radio  and  television  reception.  However,  there  is  no  guarantee  that  interference  will  not  occur  in  a 
particular  installation.  If  this  device  does  cause  such  interference,  which  can  be  verified  by  turning  the  device  off  and  on,  the  user  is 
encouraged to eliminate the interference by one or more of the following measures: 
– Re-orient or re-locate the receiving antenna. 
– Increase the distance between the device and the receiver. 
– Connect the device to an outlet on a circuit different from the one which supplies power to the receiver. 
– Consult the dealer or an experienced radio/TV technician. 

Note:

 

The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such 

modifications could void the user's authority to operate the equipment. 

 

Reviews: