TESTING THE SYSTEM
D-307503 PowerMaster 360 User's Guide
49
Additional Information (Periodic Test)
1
Display shown in disarm state when all zones are secured (00:00 or other digits show present time).
2
If you have not already changed your personal code number, use the default setting – 1111.
3
If the INSTALLER CODE is used to enter the Periodic Test instead of the USER CODE, the devices LED will
also provide the link quality indication – see PowerMaster-360 Installer's Guide.
4
To skip the SIRENS TEST and select the other devices TEST, press
.
5
The Periodic test can be performed on a maximum of two wireless sirens and the sirens of enrolled smoke
sensors. Outdoor sirens are activated with low volume.
6
If no temperature sensor is enrolled in the system, the display reads
"NO EXISTING DEV.
".
7
The displayed temperature can be in Celsius or Fahrenheit according to the programmed settings of the
Temperature Sensor.
8
To activate system devices during the "Periodic Test"; make sure the device LED lights when activated:
Contact sensor:
Open or close the door or window protected by the contact.
Motion sensors:
Perform a "walk test" of the detector as explained in the detector's datasheet.
Smoke sensors:
Perform a "Diagnostic test" as explained in the detector's datasheet.
Keyfob:
Activate any of the keyfob buttons.
Keypads:
Perform a disarm or arm routine or press any other key that activates the LED.
Repeater:
Follow the "Diagnostic Tests" described in the repeater's datasheet.
Other devices:
In general, follow the "Diagnostic Tests" described in the device's datasheet or
activate any of its functions.
9
a. Three seconds after the device is displayed, the device LED blinks to assist you to identify (
"it's me"
).
b. To end the session, press the
button until the display reads
[
<OK> TO EXIT
]
and then press
.
10
Testing emails must first be configured (see Chapter 4, B.12 “EMAIL BY SERVER”).
Periodic test per partition
In addition to the regular Periodic Test, you can also test zones for enrolled sensors (excluding temperature
sensors and sirens) that are assigned to a selected partition.
A. To conduct the periodic test per partition
1
1.
P1:R P2:N P3:-
Make sure the selected partition is disarmed and the other partitions are not
in exit or entry delay and then press the partition (
) button.
MEMORY
TROUBLE
2.
SELECT PARTITION
When the display reads [
SELECT PARTITION
], press the partition number of
the zones you wish to test, for example,
(Partition 1).
3.
Partition 1
4.
Press the
button repeatedly until the display reads [
PERIODIC TEST
]
and press
.
PERIODIC TEST
5.
ENTER CODE:
The screen will now prompt you to enter your Master user code.
6.
CODE
Enter your Master user code.
2
P1 SENSORS TEST
3
7.
To enter the devices test procedure per partition, press
.
8.
NOT ACTIVE NNN
The display reads [
NOT ACTIVE NNN
]. NNN indicates the number of enrolled