![Visonic Fully supervised wireless accessories Accessories Manual Download Page 13](http://html.mh-extra.com/html/visonic/fully-supervised-wireless-accessories/fully-supervised-wireless-accessories_accessories-manual_1032802013.webp)
SMD-426, SMD-427
12
D-302758
The PowerMax10-G2 display will read [
Fire Siren
].
6.
Press the
OK
I
button.
The PowerMax10-G2 display will read [
enable
].
OK
I
7.
Press the
or
button to select between "
enable
" and
"
disable
", for example, "
disable
".
or
8.
Press
OK
I
to confirm the selection.
The PowerMax10-G2 display will revert to [
Fire Siren
].
OK
I
9.
Press the
button.
The PowerMax10-G2 display will read [
Gas / CO Siren
].
10.
Press the
OK
I
button.
The PowerMax10-G2 display will read [
enable
].
OK
I
11.
Press the
or
button to select between "
enable
" and
"
disable
", for example, "
disable
".
or
12.
Press
OK
I
to confirm the selection.
The PowerMax10-G2 display will revert to [
Gas / CO Siren
].
OK
I
13.
Press the
button.
The PowerMax10-G2 display will read [
Flood Siren
].
14.
Press the
OK
I
button.
The PowerMax10-G2 display will read [
enable
].
OK
I
15.
Press the
or
button to select between "
enable
" and
"
disable
", for example, "
disable
".
or
16.
Press
OK
I
to confirm the selection.
The PowerMax10-G2 display will revert to [
Flood Siren
].
OK
I
When exiting "
ZONES / DEVICES
" menu the PowerMax10-G2 system displays the
number of devices that need to be updated, as follows: DEV UPDATING NNN.
For detailed instructions on ADDING DEVICES, DELETING DEVICES and
MODIFYING DEVICES see the PowerMax10-G2 Installer Guide.
6. SMOKE DETECTOR TEST
Enter the test mode by pressing the test button for 2
seconds and release it. In this mode, the detector will test
smoke, heat and battery functions. If all functions are
good, the red LED lights 0.5s, off 0.5s, the yellow LED
lights 0.5s, off 0.5s followed by a loud 3-beep alarm and
the red LED flashes simultaneously. Otherwise, the
detector produces the warning signals as detailed in
Table 1
.
If the detector is in any diagnostics mode, the detector
performs the diagnostics test as described in section 6.1.
6.1 Diagnostics Test
Caution!
The diagnostics test cannot be performed while
tamper is in "open" state.
A.
The detector performs a LED communication test.
B.
When the LED lights orange (red and green), this
indicates correct operation of the LEDs.
C.
The detector now performs the link quality test.
Note:
If the detector is not in local diagnostics or
installer diagnostics mode, the detector will not perform
the link quality test.
Flood Siren
disable
disable
enable
Flood Siren
Gas / CO Siren
disable
disable
enable
Gas / CO Siren
Fire Siren
disable
disable
enable
Fire Siren