Warning!

To comply with FCC and IC RF exposure compliance requirements, the device should be located at a distance of at least 20 cm from all

persons during normal operation. The antennas used for this product must not be co- located or operated in conjunction with any other antenna or
transmitter.

This device complies with Part 15 of the FCC Rules and RSS- 210 of Industry and Science Canada. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux
deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique
subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.

W.E.E.E. Product Recycling Declaration

For information regarding the recycling of this product you must contact the company from which you orignially purchased it. If you are discarding this product and not returning it for repair then
you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste.
Directive 2002/96/EC Waste Electrical and Electronic Equipment.

APPENDIX: SPECIFICATIONS

OPTICAL
Detector Type

Dual element low-noise pyroelectric sensor

Number of Curtain Beams

2

Mounting Positions

See

Figures 2 through 6

Range Settings

Maximum (6 m), Medium (4 m) and Minimum (1.2 – 2m) (remotely selected)

ELECTRICAL
Internal Battery

3V Lithium battery, type CR-123A or equivalent

Notes:

1.

Use only the above battery type.

2.

For UL installations use Gold Peak (GP) or Panasonic CR123A only.

Nominal Battery Capacity

1450 mA/h

Low Battery Threshold

2.45 V

Battery Life (for typical use)

7 years

FUNCTIONAL
Visual indications:

Red LED lights

for about 2 seconds upon motion detection in the walk test mode and for about 0.2

sec. for tamper messages.

Red LED blinks

during the power-up stabilization period (approx. 1 min), or after restoring the

cover (by pressing the tamper switch).

Red LED does not light

upon transmission of supervision messages.

Alarm Period

Approx. 2 seconds

WIRELESS
Frequency Band (MHz)

Europe and rest of world:

433-434, 868-869

USA:

912-919

Maximum Tx Power

10 dBm @ 433 MHz, 14 dBm @ 868 Mhz

Communication Protocol

PowerG

Supervision

Signaling at 4-min. intervals

Tamper Alert

Reported when a tamper event occurs and in any subsequent message, until the tamper switch is
restored

MOUNTING
Height

1.8 - 2.4 m (6 - 8 ft).

Installation Options

See

Figures 9 through 13

ACCESSORIES

BR-1:

Surface mounted swivel bracket, adjustable 30° down and 45° left/45° right.

BR-2:

BR-1 with a corner adapter

BR-3:

BR-1 with a ceiling adapter

Note:

UL did not evaluate the product with the use of the BR brackets

ENVIRONMENTAL
RFI Protection

>20 V/m up to 2000 MHz, excluding inband frequencies

Operating Temperatures

-10°C to 50°C (14°F to 122°F) indoor

Note:

UL tested 0°C to 49°C

Storage Temperatures

-20°C to 60°C (-4°F to 140°F)

Humidity

Average relative humidity of approximate 75% non-condensing. For 30 days per year relative
humidity may vary between 85 % and 95 % non-condensing.

Note:

For UL installations, relative humidity is 85%.

PHYSICAL
Size (H x W x D)

105 x 35 x 30 mm (4-1/8 x 1-3/8 x 1-3/16”)

Weight (with battery)

60 g (2.1 oz).

Color

White

PATENTS

U.S. Patents 5,693,943 • 6,211,522 • D445,709 (another patent pending)

D-303370 CLIP PG2 Installation Instructions

7

Summary of Contents for CLIP PG2

Page 1: ...ng features l For use with all PowerMaster control panels version 13 and higher l 2 way PowerG protocol communication l Very low current consumption l Microprocessor controlled temperature compensation l Sealed chamber protects the optical system l Front cover tamper switch l Optional back tamper switch l White light protection l Elegantly styled sturdy case l RF Link quality indication Detailed c...

Page 2: ...ns of burglar and Holdup Alarm Systems 2 2 Regular Mounting Note Mount the detector so that its orientation is perpendicular to the expected intrusion path A Enroll button B Front tamper switch C RF Module D Sensor E LEDs F Back tamper switch optional G 3 Volt Lithium battery A Back tamper switch A back tamper alert is activated when the base is detached from the wall Figure 7 Internal View Figure...

Page 3: ... used for EN installations Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used battery according to manufacturer s instructions 2 3 Bracket Mounting Note Mount the detector so that its orientation is perpendicular to the expected intrusion path Note When mounting using the bracket the back tamper becomes inoperative 1 Drill two 7 mm 1 4 holes at the marked locatio...

Page 4: ... Securing Locking Plate to Base 1 Position the PCB correctly in the base 2 Insert the screw to secure the cover with the base Figure 13 Mounting Cover to Base A Window Note The CLIP PG2 can be mounted on either side of a window Figure 14 Mounting on Both Sides of a Window D 303370 CLIP PG2 Installation Instructions 4 ...

Page 5: ...See Note 1 Enroll the device or Enter the device ID Select the desired Zone Number Configure Location Zone Type Chime Parameters Configur e the Detector 02 ZONES DEVICES ð ADD NEW DEVICES 6 MODIFY DEVICES ð ENROLL NOW or ENTR ID XXX XXXX ð Z03 Motion Sens ID No 122 XXXX ð Z03 LOCATION Z03 ZONE TYPE Z03 SET CHIME Z03 DEV SETTINGS ð ðmeans scroll wwand select OK See Note 2 Notes 1 If the detector is...

Page 6: ...lares that the radio equipment type CLIP PG2 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address http www visonic com download center EN 50131 1 Security Grade According to EN 50131 1 2006 and A1 2009 this equipment can be applied in installed systems up to and including Security Grade 2 EN 50131 1 Environmenta...

Page 7: ...thium battery type CR 123A or equivalent Notes 1 Use only the above battery type 2 For UL installations use Gold Peak GP or Panasonic CR123A only Nominal Battery Capacity 1450 mA h Low Battery Threshold 2 45 V Battery Life for typical use 7 years FUNCTIONAL Visual indications Red LED lights for about 2 seconds upon motion detection in the walk test mode and for about 0 2 sec for tamper messages Re...

Page 8: ...ect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty will be credited or replaced at the Seller s option THIS WARRANTY IS EXCLUSIVE AND EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES OBLIGATIONS OR LIABILITIES WHETHER WRITTEN ORAL EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A P...

Page 9: ...by their own warranty if any The Manufacturer shall not be liable for any damage or loss whatsoever whether directly indirectly incidentally consequentially or otherwise caused by the malfunction of the Product due to products accessories or attachments of others including batteries used in conjunction with the Products This Warranty is exclusive to the original Purchaser and is not assignable Thi...

Reviews: