14
The maximum current supported by the lamp output is 3A, which is 660 W at 220
VAC and 330 W at 110 VAC.
11.8.
AC Power Supply Cable Plug
Warning: Risk of electric shock! Plug installation shall be performed by a qualified
electrician.
A grounding-type (earthed) power plug that fits the local power outlet must be used.
You can acquire an IEC power cable with a suitable grounding-type plug from most of
consumer electronics stores.
When installing the plug connect pins as follows:
▪
Yellow and green wire to grounding (earth)
▪
Blue wire to neutral
▪
Brown wire to live
Good light measurements rely on stable main supply. If mains supply is insufficient
the light source can be supplied via an external power supply. Se more in the Light
Inspector software manual.
11.9.
Connecting Diagram
Below there is the connection diagram showing the different connections in order to
make the system operational.