Page 12
LGR User Guide and Technical Manual
You can also access the Status page when you click the
logo in either
the LGR [or AirStream] Web pages. The LGR Web pages can be accessed from a
PC or laptop connected to a LAN port on the LGR-1000. The default IP address is
http://
192.168.2.200
/. You can also address a static IP on a PC within that network
range [for example: http://
192.168.2.50
/]. The default user ID and password is
admin
.
You can also set the WAN IP to DHCP and click
Save Changes
, to access a WAN IP
address by which you may route the AirStream transmissions. Refer below to the
LGR
Network Settings Web Page
section
.
Mouse-over help is also available throughout the Web pages.
Current Status
Select a Channel to Monitor
Use the drop-down to select a channel from 1 to 6.
Incoming Throughput
This graphic displays the bit rate of the incoming video feed from the individual cellular
carriers for the selected channel. The combined throughput is also displayed.
RTT
[
Round Trip Time
]
This graphic displays the Round Trip Time for the signal from the transmitter to the
LiveGear Receiver.
Utilization Rate
This graphic displays the rate that the bandwidth is used to transmit the signal.
Interface Details
The Interface Details table includes the following data:
• Interface
• Carrier
• Service
• RSSI
• SNR
• SIMID
• Status