VP-4 Pager – Programming User Guide – Version 1.01
3
Note
: The section below applies to pagers with versions prior to
8108-V4
.
Manual Programming Mode
The manual programming provides access to the settings of 6 capcodes, baud rate, frequency and data polarity.
1.
Insert a battery and turn on the pager.
2.
a. Press the
▲
key until the graphic menu is displayed.
b. Press the
►
key until the display shows
ON/OFF PAGER
.
c. Press the
▲
key to turn off the pager.
3.
Press and hold both the
◄
and
►
keys until the password screen is displayed.
4.
Enter the password using the
►
key to select a digit and press
▲
key to navigate to the next password digit. After the 4th digit
was entered, press the
READ/ON-OFF
key.
Note
: Default password is
1141
.
Changing Capcodes
1.
Enter the manual programming mode as described in the Manual Programming Mode section. The display will show
ADSYSBFRQT
.
2.
a. Verify that the
AD
field is underlined or use the
►
key to navigate the cursor to the
AD
field.
b. Press the
▲
key.
3.
The display will show “
1:
CCCCCCC
0
”, where CCCCCCC is the capcode already programmed in to the pager.
The first digit label represents the number of the capcode (capcode ID) to be edited. For example, 1 represents capcode #1 and 6
represents capcode #6.
4.
Select the ID of the capcode to be edited using the
▲
key.
5.
Press the
►
key. The cursor will move to the
CAPCODE
field.
6.
a. Use the
▲
key to enter a respective capcode digit for each underlined digit in the capcode field.
b. Press the
►
key to navigate to the next digit.
c. After the rightmost digit was entered, press the
►
key. The cursor will move to the
ON/OFF
field.
Note
: Standard capcode range is from 0000008 to 2097151. Invalid capcodes will be rejected.
7.
Use the
▲
key to toggle between
0
(ON) and
1
(OFF) for the selected capcode. If you wish the capcode to be active, select
0
(ON).
8.
Press the
►
key. The cursor will move to the capcode ID field.
9.
To program additional capcodes, press the
▲
key to select the capcode to be programmed and repeat steps 5-8 for each capcode.
Otherwise, press the
READ/ON-OFF
key to return to the main programming menu.
10.
a. If additional programming is not required, press the
►
key until the cursor is under the
QT
field.
b. Press the
▲
key exit the programming mode and return to standard operation mode.