background image

VP-4 Pager – Programming User Guide – Version 1.01 

 

2

 

Changing Baud Rate and Polarity 

 
1.

 

Enter the manual programming mode as described in the Manual Programming Mode section. The display will show 

ABFLPq

 

2.

 

a. Press the 

 key to position the cursor under the 

B

 field. 

b. Press the 

READ/ON-OFF

 key. 

 

3.

 

The display will show a sequence of characters in the following format: "

BPS 

BBBB

 

PPP

"

. Use the 

 and

 

 keys to select the 

preferred setting. Below is the description of each field: 

 

BBBB

 – Baud Rate 

512 bps, 1200 bps, 2400 bps 

PPP

 – Polarity

 

Nrm – Normal, Inv – Inverted 

 

4.

 

Press the 

READ/ON-OFF 

key to return to the main programming menu. 

 

5.

 

a. If additional programming is not required, press the 

 

key until the cursor is under the 

q

 field. 

b. Press the 

READ/ON-OFF

 key to exit the programming mode and return to standard operation mode. 

 
 

Changing Frequency 

 
1.

 

Enter the manual programming mode as described in the Manual Programming Mode section. The display will show 

ABFLPq

 
Note

: If the 

F

 field in not displayed on the pager’s programming menu, the manual frequency programming feature is not 

supported by the pager. 
 

2.

 

a. Press the 

 key to position the cursor under the 

F

 field. 

b. Press the 

READ/ON-OFF

 key. 

 

3.

 

The display will show “FREQ:

FFF.FFFFF

”, where 

FFF-FFFF

 is the frequency programmed in to the pager. 

 

4.

 

a. Use the 

 key to enter a respective frequency digit for each underlined digit in the frequency field. 

b. Press the 

 key to navigate to the next programmable digit. 

c. After the rightmost digit was entered, press the 

 

key. The cursor will return to the first available frequency digit. 

 

Note

: The frequency must be within the frequency band supported by the pager (refer to the label at the back of the pager). 

Invalid frequency or a frequency not within the band supported by the pager will render the pager inoperable. 

 
5.

 

Press the 

READ/ON-OFF

 key to return to the main programming menu. 

 

6.

 

a. If additional programming is not required, press the 

 

key until the cursor is under the 

q

 field. 

b. Press the 

READ/ON-OFF

 key exit the programming mode and return to standard operation mode. 

 
 

Changing Password 

 
1.

 

Enter the manual programming mode as described in the Manual Programming Mode section. The display will show 

ABFLPq

 

2.

 

a. Press the 

 key to position the cursor under the 

P

 field. 

b. Press the 

READ/ON-OFF

 key. 

 

3.

 

a. Use the 

 key to enter a respective password digit for each underlined digit in the password field. 

b. Press the 

 key to navigate to the next programmable digit 

 

4.

 

Press the 

READ/ON-OFF

 key to return to the main programming menu. 

 

5.

 

a. If additional programming is not required, press the 

 

key until the cursor is under the 

q

 field. 

b. Press the 

READ/ON-OFF

 key exit the programming mode and return to standard operation mode. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for VP-4

Page 1: ...o the pager The first digit label represents the number of the capcode capcode ID to be edited For example 1 represents capcode 1 and 6 represents capcode 6 4 Select the ID of the capcode to be edited using the key 5 Press the key The cursor will move to the CAPCODE field 6 a Use the key to enter a respective capcode digit for each underlined digit in the capcode field b Press the key to navigate ...

Page 2: ...y programmed in to the pager 4 a Use the key to enter a respective frequency digit for each underlined digit in the frequency field b Press the key to navigate to the next programmable digit c After the rightmost digit was entered press the key The cursor will return to the first available frequency digit Note The frequency must be within the frequency band supported by the pager refer to the labe...

Page 3: ...CCCC is the capcode already programmed in to the pager The first digit label represents the number of the capcode capcode ID to be edited For example 1 represents capcode 1 and 6 represents capcode 6 4 Select the ID of the capcode to be edited using the key 5 Press the key The cursor will move to the CAPCODE field 6 a Use the key to enter a respective capcode digit for each underlined digit in the...

Page 4: ...o June 2011 or for non standard frequency ranges If the FR field in not displayed on the pager s programming menu the manual frequency programming feature is not supported by the pager VHF pagers may not support manual frequency modification although FR field is displayed In that case the pager will have to be sent back to Visiplex for reprogramming or the frequency may be changed using an optiona...

Reviews: