background image

 

 

13 

 
 
 
 
 
 
 
 

40K cavitation system: 

 

 

  

 Energy setting:From 01-10,general from beginning of 5

                                            according to the customer's specific circumstances. 

  Time setting:10-15minutes. 

 

   

Start/Stop 

Sound

 

 

Then click 

  button to return to the main menu system selection. 

 

 

 

 

Summary of Contents for vbc987

Page 1: ......

Page 2: ...ice 4 5 Summarize Theory 6 8 Application Treated Scope 9 Diagram of Accessories 10 12 Operation Steps 12 System Interface 13 18 Compare Effect 19 Application to the crowd 20 Taboos 21 Technical Parame...

Page 3: ...ud and strong noise C Cable is broken D The equipment is fallen down and broken E When you Pull out the laser pad connection 1 4 Please don t put anything on the cables don t place the equipment at an...

Page 4: ...unds serious and progressive illnesses cancer AIDS hepatitis blood diseases etc or blood coagulation problems Do not apply the device if you have or have had phlebitis after veins surgery within the l...

Page 5: ...have no improvement or if in any doubt on the use consult your doctor 2 14 Effect may vary depending on your age life habits level of physical activity diet etc 2 15 The machine can be used after any...

Page 6: ...e normally released from fat cells when the body needs energy once released the glycerol and free fatty acids are used by the body as an energy source Adipose cells shrink significantly resulting in i...

Page 7: ...mpact effect resulting in cavitation benefits Due to the formation of cavitation bubbles with the surrounding medium small vibration and constant movement growth or a sudden burst In fat cells produce...

Page 8: ...er thighs as well as smaller areas of the body such as redefining the jaw line neck and chin area It carries fewer risks as traditional liposuction and is a less invasive surgical procedure requiring...

Page 9: ...les re shaping body contour 6 Feature 1 Adopt the leading edge technology ultrasonic lipolysis in the world 2 Color touch screen with clear treatment parameters friendly operation 3 Digital frequency...

Page 10: ...9 8 Diagram Of The Accessory 8 1 Lipo Laser Pad big Lipo Laser Pad small...

Page 11: ...10 Cavitation Vacuum...

Page 12: ...ers will be placed over the appropriate lymphatic glands and held in place 93 The Laser Lipo BCS will then be switched on for 10 minutes re located and turned on for another 10 minutes this will be re...

Page 13: ...12 10 System interface Please select the technology according to customer needs to enter into the operation screen...

Page 14: ...system Energy setting From 01 10 general from beginning of 5 according to the customer s specific circumstances Time setting 10 15minutes Start Stop Sound Then click button to return to the main menu...

Page 15: ...the customer s specific circumstances Time setting 10 15minutes Negative setting Breathe in 200Ms Put gas 1000Ms Breathe in 400Ms Put gas 200Ms Breathe in 500Ms Put gas 400Ms Breathe in 2000Ms Put gas...

Page 16: ...er s specific circumstances Time setting 10 15minutes Continuous wave setting Suitable for stubborn fat or highly Obese type or according to customer needs Pulse wave setting Suitable for arms thighs...

Page 17: ...ting 15 20 minutes Energy setting From 01 0 general from beginning of 5 according to the customer s specific circumstances Press work or stop button the lipo laser system will be working stop working...

Page 18: ...g to the customer s specific circumstances Press work or stop button the lipo laser system will be working stop working Mode D Only one samll lipo laser pads will be working Time setting 15 20 minutes...

Page 19: ...18 11 Compare Effect...

Page 20: ...which makes the body fat metabolism disorders Metabolism decreasing will cause obesity reduce the number of female menstruation 5 Women s figure after childbirth breast feeding or weaning generally c...

Page 21: ...t healed up 15 5 Acute inflammation or epidemical patients 15 6 Whom with heart diseases or with heart pacemaker 15 7 Whom with kidney gall stone disease 15 8 Who was embedded metal object or silica g...

Page 22: ...Length 635 650nm Maximum Output Power 400W Single Output 50mW Number Of Diode 6x9 2x3 60diode Timer 30 minutes max Output Frequency 1Hz to 1000Hz adjustable Cavitation 40Khz Vacuum with RF 1MHz Multip...

Page 23: ...nge your life while doing the sessions Q What do you do to keep the fat off Normal things you need to keep weight off diet and exercise drinking water etc Q Where Does the Fat Go That fat can be burne...

Page 24: ...e caused by using the machine in a wrong way 2 We suggest the client to take photos of the area where the problem occurs we will pass them to our technician our technician will give a satisfactory ans...

Page 25: ...ion of the machine we will not notice you in addition If any queries please feel free to contact with the local marketing company All in one we will try our best to serve you and also need your fully...