Set Strike-out Alarm
The strike-our alarm will engage after 10 failed card attempts. Factory is OFF. The strike-our alarm ca be set to
deny access for 10 minutes after engaging or it can be set disengage only after entering a valid card or Master
code.
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set alarm time
6 0 #
(factory default)
6 1 #
Access will be denied for 10 minutes
6 2 #
5 (0 ~ 30) #, factory default is 1 minute
Enter Master code # or valid user card to
silence
3. Exit
*
Set Audible and Visual Response
Programming Step
Keystroke Combination
1. Enter Program Mode
*
(Master Code) #
2. Control Sounds
OR
2. Control LED
OFF =
7 0 #
OFF =
7 4 #
ON =
7 1 #
ON =
7 5 #
(Factory defaults are ON)
3. Exit
*
Users Operation:
Open the door: Read the valid user card on the Infrared Remote Control, the door will open.
Remove Alarm: Read valid user card on the Infrared Remote Control, or Input Master Code #
Reset to Factory Default:
To reset to factory default, power off, press the Exit Button, hold it and power on, there will be two beeps, and the
LED light turns into yellow, release the exit button, then read any two 125KHz EM card, the LED will turn into red,
means reset to factory default successfully. Of the two cards reading, the 1
st
one is Master Add Card, the 2
nd
one
is the Master Delete Card.
Remarks: Reset to factory default, the user’s information is still retained.