background image

Press  00  new code #   repeat new master code # 

Note: Master Code length: 6~8 digits 

8.1 Change the master code

5

7.4 User Optional Setting

1. Master code must be 6-8 digits, Anti-duress PIN must be 8 digits, user PIN is

    4-6 digits. 

2. The user ID number is 1-4 digits ,which can be any number among 1-2000,Invalid

    0 can be omitted; card number must be 8 or 10 digits, if the card number is 

    less than 8 or 10 digits, input 0 before the card number. 

3. Door open time is 0-99 second,0=50mS 

4. When register one card user into the device, the device will automatically generate 

    a PIN 1234, but this PIN 1234 can’t open the door, you need to change PIN 

    1234 to other numbers to open the door.  

5. When an invalid master

 pin is pressed, the device will go back to the standby 

    status after 5 seconds, when a valid 

master pin is entered, it will go back to 

    standby status after 30 seconds. 

6. In operating the keypad, pressing # means to confirm the input digits ,In operation

    of a cycle adding or deleting cards, pressing # means to end the cycle 

    operation and back the up operation; pressing * means to exit the operation. 

7. When add a series cards, this unit will make the ID number and card number as 

    initial value; after adding one user, then it will increase the ID number and 

   card number automatically, until the specified number of card is added.The card 

    number must be consecutive card quantity is between 1-2000.

8. Working mode and keypad transmission format have been set before shipping,

   customer can change according to requirement, but cannot be restored to 

   factory 

settings by initialization.   

9. When users is registered successfully, LED will turn green. 

   

  

Instruction:

8. Administrator Setting 

Administrator setting on keypad 

Press      Master code  #  factory default:999999 

*

0 # 

41

42

43

1 # 

Default 1 

Default 1 

Default 2

0 # 

1 # 

0 # 
1 # 

2 # 

Orange

Setting

Remarks

Functions

Stand

by

Red 

Flash

*

Master 

Code

Red 

Menu

Red 

Master 

code# 

(Code 

length:

6-8 

digits) 

Buzzer will be in silence except 

enter the programming mode

Buzzer will sound when press

the key
Disable keypad backlight

Enable keypad backlight

Automatic mode

LED is constantly flash when 

stand-by status

LED Light Disable when 

stand-by status

Summary of Contents for VIS-3002

Page 1: ...Standalone Access Control for Single Door www visionistech com User Manual VIS 3002 ...

Page 2: ... than 30mA Input Output Wiegand26 Searching Time Less than 0 1s after reading card Backlight Keypad Easy to operate at night Doorbell interface Support external wired doorbell Access ways Card code card code Independent codes Use codes without related card Change Codes Users can change codes by themselves Anti tamper alarm Alarm is activated after tear down illegally Delete Users by card NO Delete...

Page 3: ...ntact 9 ALARM Gray Alarm Output 10 NO Blue Relay NO end 11 COM Purple Relay Com end 12 NC Orange Relay NC end 2 6 Sound and Light Indication Operation LED Color Buzzer Standby Red flash Press key Di Read card Green Di Door Open Green Di Operation Successful Green Di Operation Failed Di Di Di PIN Inputting Red Card PIN Inputting Red Multi Card Reading Red Under Menu Red Under Setting Orange Manager...

Page 4: ...dd Card Set Manager Delete Card Set Anti duress card Set Anti duress PIN Delete All Users Master open Lock 7 2 System Setting Master Code Menu Setting Remarks Default 0 Default 0 Default 1 Default 26 Unable to initialize Unable to initialize Functions To set facility code Wiegand reader mode Anti passback mode To set alarm time Safe mode 0 Safe mode 1 Safe mode 2 To set keypad transmission format ...

Page 5: ...lse mode Relay Setting Toggle mode To set open door by multi cards To add a series cards users Users can be deleted continuously without exiting programming mode Card number ID number card number ID number PIN Read card ID number Card number Default 2 Default 5 Default 0 Default 1 0 1 0 1 1 10 ID number card number card quantity 2 0 99 Master Code Menu Setting Remarks Functions Stand by Red Flash ...

Page 6: ... cards pressing means to end the cycle operation and back the up operation pressing means to exit the operation 7 When add a series cards this unit will make the ID number and card number as initial value after adding one user then it will increase the ID number and card number automatically until the specified number of card is added The card number must be consecutive card quantity is between 1 ...

Page 7: ... duress PIN for one device 8 3 Set Anti duress card 8 4 Set Anti duress PIN 8 5 Delete all users 8 6 Set administer open lock 8 7 Users setting Set Anti duress PIN Press 05 8 digit duress PIN Set administer open Lock Press 51 Press 07 0000 Note All users will be deleted This is a dangerous option so use with care 8 7 1 Read card to add user 8 7 2 Use ID Number and read card to add user Press 11 re...

Page 8: ...ll users will be deleted 8 8 Delete user 8 9 Set opening door mode 8 10 set door relay time 8 8 1 Read card to delete user 8 9 1 Entry is by card only 8 9 2 Entry is by card and PIN together 8 8 2 Use ID number to delete user 8 8 4 Delete all users 8 8 3 Use card number to delete user 8 7 4 Use ID number and card number to add user Press 11 ID number 8 digits card number ID number 8 digits card nu...

Page 9: ...opening door by multi cards 8 13 Add a series consecutive cards users Press 15 1 Relay setting Toggle mode Press 16 card quantity Press 17 ID number card number card quantity 8 14 system setting 8 14 1 To set facility code Note Code should be 0 15 factory default setting 0 8 14 2 Wiegand Reader Mode Wiegand 26 8 14 3 Standalone Mode Factory default setting 8 14 4 Anti passback Mode Press 31 0 Pres...

Page 10: ...put wrong PIN 10 times in 10 minutes system will be dead for 10 mins if read invalid card or input wrong PIN 10 times in 10 minutes external alarm and built in buzzer will work 9 User Operation 9 1 Entry by card mode Set multi cards to open door when card quantity is 1 Read user card lock will be unlocked 9 2 Entry by card mode Set multi cards to open door when card quantity is 2 10 Read these car...

Page 11: ...ally the buzzer and the external alarm will operate 10 2 Door contact alarm When connect with door contact if the door is opened illegally the buzzer and the external alarm will operate 10 3 The Anti duress alarm When read anti duress card or input 8 digit anti duress PIN then press the corresponding lock will open at the same time the external alarm will operate but the device buzzer will not ope...

Page 12: ...Connection Diagram 11 1 NO NC Locks BELL_B BELL_A 12V P ink P ink DC 12V Door Strike KEYPAD READER Normally Open BELL_B BELL_A 12V P ink P ink DC 12V maglocks electric bolt locks KEYPAD READER Normally closed ...

Page 13: ... FROM KEYPAD READER FROM KEYPAD READER OPEN YELLOW WIRE PINK WIRE FROM KEYPAD READER BELL A Door Bell YELLOW WIRE FROM DOOR BELL FROM KEYPAD READER GREEN WIRE FROM DOOR BELL Exit Button COM COM NO NO NC Power Supply Receiver Power Supply Power Supply Electromagnetic Lock Keypad Reader ORANGE WIRE FROM KEYPAD READER PINK WIRE FROM KEYPAD READER BELL B PINK WIRE FROM KEYPAD READER BELL A YELLOW WIRE...

Page 14: ...BELL_B BELL_A 12V P ink P ink D1 D0 12V GND Power Supply Electromagnetic Lock Exit Button Keypad Reader Power Supply COM NO NO PIR COM Door Bell PINK WIRE FROM KEYPAD READER BELL B GREEN WIRE FROM DOOR BELL YELLOW WIRE YELLOW WIRE ORANGE WIRE PINK WIRE FROM KEYPAD READER BELL A PURPLE WIRE FROM KEYPAD READER ...

Page 15: ...e Quantity Remarks Keypad 1 User manual 1 Self tapping screws Φ4mm 28 mm 2 Used in fixing Rubber plug Φ6mm 30 mm 2 Used in fixing Star screw driver Φ20mm 60mm 1 Special for Keypad a Please do not to repair the device privately if you have problems please return to the supplier b Before installing on the wall please check carefully concealed wiring or wire tube in case of broken concealed wiring et...

Page 16: ......

Reviews: