Technical data
Technisches Handbuch
Version 5.2
25
4.6.5
Update firmware
Caution!
An update may only be carried out if the VoE-IO boxes are connected
directly to the PC (without interconnected switches).
The update is performed using TFTP (based on UDP). Therefore any
disturbance or interruption on the network can destroy the box.
Start the program "Firmware update IOBox 2.7" from the driver CD
1. Enter the IP address of the VoE-IOBox. By default, the IP address is entered as
192.168.0.254.
2. Via the button
[query],
you can query the status of the current firmware version.
3. Enter the path of the current firmware file (
"elr4_v2.05.01.hex"
) via the folder icon.
4. Finally, press the
[update]
button.
The upload mode is detected by the flashing "LINK" LED. After a short time, the LED stops
flashing. The upload can take up to a minute depending on the hardware used.