background image

20 

 
 
 
 
 
 

 
 
 
 
   

(Fig. O)

                                 

 

3.If the console cable is good and the console is still not lit, the PCB is defective and replace 

the console. 

Summary of Contents for E1500 Frame 9

Page 1: ...1 BECS_9 Service manual E3200 Frame_9 E1500 Frame_9 R2250 Frame_9 R1500 Frame_9 X6200 Frame_9 X1500 Frame_9 X20 Frame_09 ...

Page 2: ...RAMS 4 1 RB130 2KM C BECS_9 8 4 2 CB142B 2KM F E3200 FRAME_9 9 4 3 CB143 2KM F E1500 FRAME_9 10 4 4 RB135 2KM F R2250 FRAME_9 11 4 5 RB133 2KM F R1500 FRAME_9 12 4 6 EP225 2KM F X6200 FRAME_9 13 4 7 EP224 2KM F X1500 FRAME_9 14 4 8 EP240 2KM F X20 FRAME_9 15 CHAPTER 5 ERROR CODE 5 1 E1 NO CONNECT ECB MOTOR 15 CHAPTER 6 TROUBLESHOOTING 6 1 TROUBLESHOOTING NO RPM 15 6 2 TROUBLESHOOTING RESISTANCE IN...

Page 3: ...3 CHAPTER 1 SERIAL NUMBER LOCATION 1 1 Serial Number Location E3200 Frame_9 E1500 Frame_9 R2250 Frame_9 R1500 Frame_9 X6200 Frame_9 X1500 Frame_9 X20 Frame_09 Serial Number Placement ...

Page 4: ...is key in setup mode to select your program exercise time and resistance level D START PAUSE HOLD RESET KEY Press the START key to begin exercising in manual mode at the set default time When exercising press the START key to pause your workout To reset press and hold the START key for three seconds E UP OR DOWN ARROWS Use these keys to change program number exercise time and resistance level in s...

Page 5: ...or time remaining in your workout DISTANCE the total distance traveled in miles or kilometers since the start of the workout HEART RATE displays your heart rate in beats per minute when using the hand pulse grips CALORIES an estimate of calories burned since the start of the workout WATTS a measurement of workload It is determined by resistance level and stride rate 2 3 USE THE SIMPLE CONSOLE QUIC...

Page 6: ... workout resistance level Press ENTER to select CHAPTER 3 ENGINEERING MODE 3 1 ENGINEERING MODE 1 To enter Engineering Mode press hold the resistance UP or DOWN keys at the same time for 3 5 seconds until Engineering mode Eng1 first appears on the display 2 Use the resistance UP or DOWN keys to select a parameter 3 Press ENTER to enter a parameter setting 4 Press the START key to save the change t...

Page 7: ...min Press UP to increase Press DOWN to decrease Hold ENTER 2 sec to save new setting Press START back to Engineering Menu Eng 5 Default Level Setting From L1 to L16 Press UP to increase Press DOWN to decrease Hold ENTER 2 sec to save new setting Press START back to Engineering Menu Eng 6 Product Selection Model Configuration Press the UP or DOWN keys to select EP or Bike Press the ENTER key to sav...

Page 8: ...8 CHAPTER 4 ELECTRON DIAGRAMS 4 1 RB130 2KM C BECS_9 ...

Page 9: ...9 4 2 CB142B 2KM F E3200 FRAME_9 ...

Page 10: ...10 4 3 CB143 2KM F E1500 FRAME_9 ...

Page 11: ...11 4 4 RB135 2KM F R2250 FRAME_9 ...

Page 12: ...12 4 5 RB133 2KM F R1500 FRAME_9 ...

Page 13: ...13 4 6 EP225 2KM F X6200 FRAME_9 ...

Page 14: ...14 4 7 EP224 2KM F X1500 FRAME_9 ...

Page 15: ...onnect ECB motor CHAPTER 6 TROUBLESHOOTING 6 1 No RPM Reason 1 Bad connection between the console wire and the console 2 Speed Sensor wire is defective 3 Speed Sensor Assembly Un properly 4 Loss magnet from the pulley 5 Console wire is defective 6 Console defective ...

Page 16: ... blocks are flashed Fig E the speed sensor works well If the left 8 blocks are not flashed the speed sensor wire is defective or it is not well assembled Replace the sensor speed wire if it is defective Fig E 3 Check the gap between speed sensor and the magnet on the pulley It is normal within 5mm Fig F Adjust it if the gap is too big Fig F 4 Re install a new magnet Fig G if it is missed from the ...

Page 17: ...tor works Enter Engineering Mode See Chapter 3 and scroll to ENG 2 Machine Test Press the key ENTER first and then press the resistance UP or DOWN keys The left window display the rounds of ECB motor moving If the figure is up or down the ECB motor works well If it is always 0 the ECB motor or the wiring is defective Replace the ECB motor if it is defective Fig H 2 A Inside Magnetic Brake Control ...

Page 18: ...frame Fig K Fig K 3 If the console wire the console the ECB motor all work well the magnetic brake control equipment is defective Replace it 6 3 No Power to the Console Symptom The adaptor and power switch is in the on position but the console will not turn on Reason 1 The Adaptor is defective 2 The console wire is defective 3 The console is defective Solution Adjust the steel cable Distance away ...

Page 19: ...ti meter to check the negative and positive of power switch If the multi meter displays output DC 12V then the power switch is good If it is not the power switch is defective and replace it Fig M Fig M 2 Remove the console cable from the PCB and use a multi meter to measure the output DC voltage of the console cable pin GND and PIN VCC If it is not output DC 12V the console cable is defective and ...

Page 20: ...20 Fig O 3 If the console cable is good and the console is still not lit the PCB is defective and replace the console ...