![Vision Aqua Verdanium Home Instructions Manual Download Page 30](http://html1.mh-extra.com/html/vision-aqua/verdanium-home/verdanium-home_instructions-manual_1031714030.webp)
Instruction Manual – Verdanium Home
– Ver. 2.2.1 – 04.2021
Instruction Manual – Verdanium Home
– Ver. 2.2.1 – 04.2021
58
59
You must put the system into operation after each filter change or after a new installation. For this pur-
pose, select the commissioning program (IB-Programm) in the operating mode menu (Betriebsart).
Navigate with the ( + )- or ( - ) key to activate the operating mode, press the
OK-button
.
This operating mode (IB-Programm) assumes that the Verdanium Home is properly connected. The water
inlet and withdrawal tap must be open.
In the first pass, the program rinses the pre-filters (Filter spülen).
When rinsing the membranes (Membran spülen), the disinfectant is removed from the membrane and drains
into the waste- water connection.
During the last phase of recommissioning, the Verdanium Home rinses the ultra-pure water side of the
membranes and the post-filters (Permeat spülen).
When the IB-Programm is completed, and the extraction tap is open, the Verdanium Home changes automa-
tically to permeate production. The Verdanium Home is now ready for use.
Start-up after filter change
Filter change
This completes the annual filter change. Once the new filters are installed you can close the housing again
and screw-on the cover. Please do not use excessive force when tightening the screws.
Reconnect the Verdanium Home again to the withdrawal tap and any other connected devices, the water
supply and the drain. Restore the power supply and turn on the Verdanium Home.
Return the Verdanium Home to its original location. Please note the distance to the back wall of the cabinet
should not be less than 5 cm.
Open the water supply to the unit and check the Hydro-Stopper and its battery.
Do not use rechargeable batteries in the Hydro-Stopper; use one AA LR 6 Alkaline Battery which does not
discharge by itself and lasts in the Hydro-Stopper without any problems for one year.
Post-filter replacement
You must change the post-filter every 12 months. Refer to the illustrations below and proceed as follows:
Thanks to the tilt-able filter heads of the pre-
and post-filters, you can easily remove the filters
without additional tools. Tilt the GAC post-filter
unit forwards out of the Verdanium Home.
Turn pre-filter cartridge counterclockwise 90°
out of the filter head to change the filter unit.
Before inserting the new filter units, remove the
protective cap from the filters. You can easily
push it upwards to remove it.
Press the new filter cartridges into the filter
heads of the Verdanium Home and turn them
90 ° clockwise.
1.
2.
Automatic
Automatic
Button
BETRIEBSART
mit “+“ / “-“ Taste
auswählen
IB-PROGRAMM
ESC ← → OK
Filter spülen
ESC ← 030%
PERMEATPRODUKTION
Gerät in
Betrieb
ESC ←
Permeat spülen
ESC ← 060%
Membran spülen
ESC ← 090%