background image

LDLF60x480-G525/24V

Technical Data

5.5 Technical Drawings

Ø

 5

18.5

30

187.5

30

30

18.5

187.5

30

18

12 x M3 - depth 5.5

(on both sides)

18.5

30

187.5

187.5

30

30

18.5

22

3

A

6 x M3 - depth 4.5

11

.5

2 x M3 - depth 10.5

A

M8 connector

(on both sides)

150

15.5

3

22

30

13.5

light-emitting surface

19

480

502

60 61 66

Image 4: Technical drawings (dimensions in mm)

© Vision & Control GmbH 2019

999.995.676.10-en-1.0

19

Summary of Contents for 1-47-311

Page 1: ...ions for Use LDLF60x480 G525 24V LED bar light diffuse illumination Luminous colour Green 525 nm Instructions for Use LDLF60x480 G525 24V LED bar light diffuse illumination Luminous colour Green 525 nm 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 2: ...s this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect to patent utility sample and design patent registrations as well as for rights of use within the scope of copyright vicotar vicolux pictor vicosys and vcwin are registered trademarks of Vision Contro...

Page 3: ...LF60x480 G525 24V 1 47 311 Product Identification Designation Description LDLF LED bar light diffuse illumination 60x480 Dimensions light emitting surface 60 mm x 480 mm G525 Wavelength Green 525 nm 24V 24 V DC operating voltage with integrated lighting controller Vision Control GmbH 2019 3 ...

Page 4: ...ption 12 4 1 Device Views 12 4 2 Notices on the device 13 5 Technical Data 14 5 1 General Parameters 14 5 2 Electrical Parameters 16 5 3 Photometric Parameters 17 5 4 Conditions for Operation Storage and Transport 18 5 5 Technical Drawings 19 6 Commissioning 20 6 1 Unpacking 20 6 2 Mounting the Device 21 6 3 Connecting 22 6 3 1 Pin assignment 23 7 Operation 24 7 1 Making Operational Readiness 25 7...

Page 5: ...LDLF60x480 G525 24V Vision Control GmbH 2019 999 995 676 10 en 1 0 5 ...

Page 6: ... future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in potentially explosive areas It is intended for use in a confined environment The device may only be used if it is in technically faultless condition and only for its intended purpose and only in accordance...

Page 7: ...ions of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device 1 3 Qualified Personnel The device may only be assembled commissioned operated maintained installed set up cleaned repaired and transported by qualified skilled personnel A qualified person is deemed ...

Page 8: ...nual and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the maintenance repairs and modifications to the device are performed by himself or by authorised skilled personnel in accordance with his instructions Loss of warranty The manufacturer shall accept no liabi...

Page 9: ...ces of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medium risk possibly resulting in severe injuries or death if not avoided CAUTION Indicates a hazardous situation with low risk resulting in minor or medium injuries if not avoided NOTICE Indicates a situ...

Page 10: ...vice and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric shock Before starting work on the device disconnect it from the operating voltage supply Follow all applicable safety regulations for the preparation and operation of electrical devices 10 999 995 676...

Page 11: ... Cable with M8 socket 4 pin straight 2 m 1 11 612 Cable with M8 socket 4 pin straight 3 m 1 11 613 Cable with M8 socket 4 pin straight 5 m Connection cable with 4 pin M8 socket and open cable end with ferrules 4 x 0 5 PUR IP67 straight socket 1 11 614 Extender cable M8 4 pin Designation Description Order no M8 Extender cable 4 pin 1 5 m straight 1 11 094 M8 Extender cable 4 pin 3 m straight Extend...

Page 12: ...vice Views 4 5 1 2 3 Image 1 Device view 1 Light emitting surface 2 2 x M3 mounting hole depth 10 5 mm on both sides 3 6 x M3 mounting hole depth 4 5 mm on both sides 4 Casing 5 Connection cable with 4 pin M8 connector 12 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 13: ...ices on the device Following instructions are provided on the device Type plate Type XXXXXXXXXXX No XXXXXXXX 1 3 2 Image 2 Type plate 1 Device designation 2 Manufacturer information 3 Serial number Vision Control GmbH 2019 999 995 676 10 en 1 0 13 ...

Page 14: ...anodised Optical material PMMA Housing dimensions 66 mm x 502 mm x 22 mm without connector Dimensions light emitting surface 60 mm x 480 mm Weight 855 g Degree of protection IP IP 50 Safety class Class III safety extra low voltage SELV Risk group DIN EN 62471 Risk group 0 exempt group 14 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 15: ...Bending radius cable fixed at least 5 x cable diameter Bending radius cable moved at least 10 x cable diameter Bending cycles at least 4 million Robot suitable no Connector Parameter Characteristic Connector 4 pin M8 connector Mechanical operation 100 mating cycles Degree of protection IP IP 67 if connected Rated current 5 A Rated voltage 30 V Vision Control GmbH 2019 999 995 676 10 en 1 0 15 ...

Page 16: ...wer consumption at UO 24 V DC 24 6 W 1 Input voltage OFF 0 V 2 7 V Input current OFF 0 mA 2 mA Input voltage ON 3 7 V 30 V Input current ON 5 mA 10 mA Switch input ON OFF Input delay tD 150 µs 1 The nominal values refer to an ambient temperature of 25 C and free convection 16 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 17: ...k 520 nm Dominant Wavelength λdom 516 nm 525 nm 534 nm Spectral bandwidth Δλ 33 nm Continuous operation switchable Radiance 20 W m sr Spectral Emission Relative spectral emission Wavelength nm 0 20 40 60 80 100 450 500 550 600 650 Image 3 Spectral emission Vision Control GmbH 2019 999 995 676 10 en 1 0 17 ...

Page 18: ... original packaging For accessories connected devices and components observe the specific information in the associated instructions for use Ambient Conditions Operation Storage Transport Temperature 0 C to 45 C 25 C to 60 C Air humidity 20 to 80 20 to 95 Condensation water not permissible not permissible 18 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 19: ...8 12 x M3 depth 5 5 on both sides 18 5 30 187 5 187 5 30 30 18 5 22 3 A 6 x M3 depth 4 5 11 5 2 x M3 depth 10 5 A M8 connector on both sides 150 15 5 3 22 30 13 5 light emitting surface 19 480 502 60 61 66 Image 4 Technical drawings dimensions in mm Vision Control GmbH 2019 999 995 676 10 en 1 0 19 ...

Page 20: ... together with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard Loosening the film and forming an insertion pocket 3 Remove the device out of the insertion pocket 4 Dispose the packing material 20 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 21: ... de energised state To mount the device tapped holes are located at the sides 3 2 1 1 12 x M3 tapped hole at the bottom Maximum screw in depth 5 5 mm 2 6 x M3 tapped hole at both long sides Maximum screw in depth 4 5 mm 3 2 x M3 tapped hole at both short sides Maximum screw in depth 10 5 mm Vision Control GmbH 2019 999 995 676 10 en 1 0 21 ...

Page 22: ... may only be performed in the off and de energised state NOTICE Cable damage Comply with the specified minimum bending radius Cables must generally be mounted with a strain relief clamp Use cables corresponding to the specification see data sheet 22 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 23: ...o the pin assignment Pin assignment 1 3 2 4 Image 5 M8 male plug 4 pin Connection diagram V GND 1 3 4 BU BK BN ON OFF Pin Core colour Signal Description 1 BN brown V Operating voltage 2 WH white NC Do not use 3 BU blue GND Ground 4 BK black ON OFF Switch input Vision Control GmbH 2019 999 995 676 10 en 1 0 23 ...

Page 24: ... are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event of dazzling allow sufficient time for the eyesight to adapt to the ambient illumination before commencing other activities CAUTION Danger of burns due to hot surfaces The housing of the device can reach tempera...

Page 25: ...nuous operation The lighting is switched on by setting the ON OFF signal after the delay time td Resetting the ON OFF signal turns off the lighting Continuous operation switchable The switchable continuous operation is carried out by continuously setting and resetting the switching signal ON OFF Consider the switching delay time td of the lighting Set the exposure time of the camera to be within t...

Page 26: ...ts t Lighting t Switching signal td td tON ts Continuous operation Continuous operation td td tON switchable ts Exposure time of the camera tON Power on time td Delay time Min Nom Max Delay time td 150 µs Power on time tON 150 µs 26 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 27: ...utside with a damp cloth Remove excessive dirt with an approved anodised aluminium cleaner Refer to the instructions of the cleaner The connectors must be clean and dry before the device is connected and put into operation Cleaning the cover light emitting surface Use a soft clean cloth for cleaning The cover must be cleaned with an approved PMMA Polymethylmethacrylat cleaner Refer to the instruct...

Page 28: ... glad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstraße 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective device If the device has a defect the manufacturer can repair or exchange it Please contact your local sales partner or technical support 28 999 995 676 10 en 1 0 Vision Control GmbH 2019 ...

Page 29: ... separately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be done in accordance with the currently valid legal regulations Please contact the manufacturer your local specialist dealer or the relevant national authority for the proper disposal of old devices The el...

Page 30: ...trial environments DIN EN 61000 6 4 2011 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and measurement techniques Electrostatic discharge immunity test DIN EN 62471 2009 03 EN 62471 2008 Photobiological safety of lamps and lamp systems The product complies with the requirements of Directive 2011...

Page 31: ...LDLF60x480 G525 24V Vision Control GmbH 2019 999 995 676 10 en 1 0 31 ...

Page 32: ...Vision Control GmbH Mittelbergstraße 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH ...

Reviews: