OPERATION

6.1 Connecting the Device

Connect the device according to the pin assignment.

Figure 7:

Pin assignments/Connection diagram

NOTICE

Operate the device only using suitable power sources 
(LED or flash controllers). 
Observe the admissible parameters 

(see chapter 8 “Technical Data” on page 21)

.

The device is protected against polarity inversion and overheating 

(protection against overheating is only guaranteed in combination with 
a vicolux

®

 smart light lighting controller). 

Comply with the safety regulations for the operation of electrical instal-
lations and devices.

Pin assignments

Connection diagram

2

4

3

1

LED

LED

BN

1

WH

2

BK

4

BU

3

BD

BG

+ I

- I

Summary of Contents for 1-33-009

Page 1: ...999 994 719 10 en 1 0 Vision Control GmbH 2017 the easy way of machine vision Installation and Operating Instructions R CLR 69x41 IR860 SL Coaxial LED ring light vicolux smart light...

Page 2: ...hts concerning copyright are reserved vicotar vicolux pictor vicosys and vcwin are trademarks of Vision Control GmbH The products and brand names of other manufacturers or suppliers are mentioned for...

Page 3: ...evice 10 3 6 Dimensional Drawing 11 4 Packaging and Transportation 12 5 Installation and Mounting 13 5 1 Mounting the Device 14 5 2 Mounting the Accessories 15 5 2 1 Lens Adapter 15 5 2 2 Mounting the...

Page 4: ...t be read completely and carefully in order to avoid hazards and the need for repairs and to reduce downtimes and lengthen the service life of the device The instructions must always be present at the...

Page 5: ...tion is introduced by a key word and colour highlighted The key word indicates the degree of danger WARNING Indicates a potentially dangerous situation If this situation is not avoided fatality or ver...

Page 6: ...ork on the device when it is powered up Before starting work on the device disconnect it from the operating voltage Never remove stickers or labels from the product All labels must be kept in clearly...

Page 7: ...3 1 Intended Use The device is intended for use solely as an internal lighting element for machine vision in the field of automation technology The device may only be used in enclosed areas Safe trou...

Page 8: ...e The device is not designed for use in potentially explosive atmospheres They include the EU directives 1999 92 EC ATEX 137 and 2014 34 EU ATEX 95 but are not limited to them 3 3 Labelling of the Dev...

Page 9: ...sion Control GmbH 2017 9 170127_999 994 719 10 en 1 0 Rating plate Figure 1 Rating plate 3 4 Display and Operating Elements The device does not have any display or operating elements 1 Rating plate wi...

Page 10: ...0 Vision Control GmbH 2017 170127_999 994 719 10 en 1 0 3 5 Structure of the Device Figure 2 Structure of the device 1 Luminous field 2 Housing 3 4 pin M8 plug 4 3 x M2 5 threaded pins 5 External thre...

Page 11: ...719 10 en 1 0 3 6 Dimensional Drawing Figure 3 Dimensional drawing all dimensions in mm 3 M2 5 grub screw to clamp adapter ring 4 M3 depth 4 5 luminous field I O diameter M8 connector 11 7 12 6 3 P41...

Page 12: ...fixes the product onto the corrugated board format This ensures that slipping can be avoided The device may only be transported in its original packaging or in other suitable packaging Adapters and mo...

Page 13: ...Electronic components and modules are sensitive to electrostatic discharges Appropriate ESD protection measures must be taken before the device is mounted The device may only be connected when it is e...

Page 14: ...ere are also three threaded pins 1 attached to the side for mounting accessories A 1 5 mm allen key is needed to mount the accessories not part of the scope of delivery Figure 4 Position of the mounti...

Page 15: ...her the objective is endocentric or telecentric screw an appropriate adapter ring 1 see chapter 8 5 Accessories on page 25 into the filter thread of the lens barrel 2 or place it on the lens barrel 2...

Page 16: ...994 719 10 en 1 0 5 2 2 Mounting the Optical Accessories Figure 6 Mounting the optical accessories 1 Place the optical head 1 on the lamp surface 2 Mount the attachment ring 2 directly on the lightin...

Page 17: ...power sources LED or flash controllers Observe the admissible parameters see chapter 8 Technical Data on page 21 The device is protected against polarity inversion and overheating protection against o...

Page 18: ...ng 1 3 BU ILED LED cathode negative current input 4 BK BG Data Channel for vicolux smart light lighting 1 CAUTION Flicker dazzling and stroboscopic effects can cause psychological disturbances such as...

Page 19: ...imum permissible value of continu ous current see chapter 8 2 Electrical Parameters on page 22 Flash mode The device will be operated using current pulses permissible in flash mode Do not exceed the m...

Page 20: ...y contamination with a cleanser approved for anodised aluminium In doing so follow the instructions for using the cleanser Cleansers must not be applied directly to the housing the housing must not be...

Page 21: ...ide 41 0 mm Ring width 14 0 mm Dimension of through view 40 4 mm Plug connector M8 4 pole Length of the connecting cable 150 mm Cable type Li9Y11Y 4 x 0 5 mm2 TPU UL20549 Cable diameter outside 5 0 mm...

Page 22: ...12 A 2 The maximum values refer to an ambient temperature of 25 C if convection is unobstructed Parameters Min Nom Max Continuous mode LED current ILED 0 A 1 1 3 A 2 Forward voltage ULED 6 0 V 7 0 V...

Page 23: ...oid wavelength 850 nm Continuous mode Irradiance 210 W m Working distance 100 mm measured in the optical axis at maximum parameters Flash mode Pulse operation Irradiance 1300 W m Working distance 100...

Page 24: ...gure 8 Pulse load at ambient temperature 25 C I LED t OFF t ON Duty Cycle D On Time t Off Time t ON OFF D t t t ON ON OFF 0 00 2 00 4 00 6 00 8 00 10 00 12 00 1 0 E 5 1 0 E 4 1 0 E 3 1 0 E 2 1 0 E 1 1...

Page 25: ...mission 8 5 Accessories A wide range of accessories are available for the R CLR 69x41 IR860 SL lighting unit for example optical heads diffusers and adapter rings You will find more detailed technical...

Page 26: ...r the proper disposal of old devices can be obtained from the manufacturer local sales partner or relevant national authority Alternatively the device can be returned to the manufacturer for proper di...

Page 27: ...tion is made to the device that we have not authorised Manufacturer Vision Control GmbH Mittelbergstra e 16 D 98527 Suhl Germany Description of the device Designation Coaxial LED ring light vicolux sm...

Page 28: ...R CLR 69x41 IR860 SL List of Changes 28 Vision Control GmbH 2017 170127_999 994 719 10 en 1 0 11 LIST OF CHANGES Version Date Contents Chapter...

Page 29: ...R CLR 69x41 IR860 SL Notes Vision Control GmbH 2017 29 170127_999 994 719 10 en 1 0 12 NOTES...

Page 30: ...R CLR 69x41 IR860 SL Notes 30 Vision Control GmbH 2017 170127_999 994 719 10 en 1 0...

Page 31: ...R CLR 69x41 IR860 SL Vision Control GmbH 2017 31 170127_999 994 719 10 en 1 0...

Page 32: ...R 69x41 IR860 SL 170127_999 994 719 10 en 1 0 Vision Control GmbH 2017 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephon 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 www vision control...

Reviews: