![VISIOMED bewell connect MyThermo Pocket BW-MTX1 Operating Instructions Manual Download Page 108](http://html1.mh-extra.com/html/visiomed/bewell-connect-mythermo-pocket-bw-mtx1/bewell-connect-mythermo-pocket-bw-mtx1_operating-instructions-manual_1031019108.webp)
BewellConnect - BW-MTX1 - User Manual - 2018-06_V1
108
by absorption and reflection from structures, objects and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) tele-
phones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast
cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due
to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured
field strength in the location in which the models model name are used exceeds the applicable RF
compliance level above, the models model name should be observed to verify normal operation.
If abnormal performance is observed, additional measures may be necessary, such as reorienting
or relocating the models model name.
b
Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V1] V/m.
Recommended separation distances between portable and mobile RF communi-
cations equipment and the models BW-MTX1
The models BW-MTX1 are intended for use in electromagnetic environment in which radiated RF
disturbances is controlled. The customer or the user of the models BW-MTX1 can help prevent
electromagnetic interference by maintaining a minimum distance between portable and mobile
RF communications equipment (transmitters) and the models BW-MTX1 as recommended
below, according to the maximum output power of the communications equipment.
Rated maximum output
power
of transmitter
W
Separation distance according to
frequency of transmitter (m)
150 kHz to
80 MHz
d=1.2×P
1/2
80 MHz to
800 MHz
d=1.2×P
1/2
800 MHz to
2.5GHz
d=2.3×P1/2
0,01
0.12
0.12
0.23
0,1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended
separation distance d in meters (m) can be estimated using the equation applicable to the
frequency of the transmitter, where P is the maximum output power rating of the transmit-
ter in watts (W) accordable to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz. the separation distance for the higher frequency range
applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is
affected by absorption and reflection from structures, objects and people.
Summary of Contents for bewell connect MyThermo Pocket BW-MTX1
Page 1: ...BewellConnect BW MTX1 User Manual 2018 06_V1 1 BW MTX1 0197 MyThermo Pocket ...
Page 4: ......
Page 5: ...BewellConnect BW MTX1 User Manual 2018 06_V1 5 0197 FR MyThermo Pocket BW MTX1 ...
Page 19: ...BewellConnect BW MTX1 User Manual 2018 06_V1 19 0197 EN MyThermo Pocket BW MTX1 ...
Page 33: ...BewellConnect BW MTX1 User Manual 2018 06_V1 33 0197 NL MyThermo Pocket BW MTX1 ...
Page 47: ...BewellConnect BW MTX1 User Manual 2018 06_V1 47 0197 MyThermo Pocket ES BW MTX1 ...
Page 61: ...BewellConnect BW MTX1 User Manual 2018 06_V1 61 0197 PL MyThermo Pocket BW MTX1 ...
Page 77: ...BewellConnect BW MTX1 User Manual 2018 06_V1 77 0197 MyThermo Pocket IT BW MTX1 ...
Page 91: ...BewellConnect BW MTX1 User Manual 2018 06_V1 91 0197 MyThermo Pocket PT BW MTX1 ...
Page 105: ...BewellConnect BW MTX1 User Manual 2018 06_V1 105 E M C D ATA ...
Page 109: ...BewellConnect BW MTX1 User Manual 2018 06_V1 109 WA R R A N T Y ...
Page 119: ......