background image

3. Installation 

The 

V Inground

 unit should be connected to the V Power driver. See V Power 60( or V Power 120, V Power 

240, V Power 600) user manual for full details of mains power requirement, built-in programs and DMX 

operation. Connect the end of the 

V Inground

’s cable directly to the driver or use suitable cable joint 

box(water-proof for outdoor installation) if the cable has to be extended.   

 

 

For the number of V Inground projectors that can be linked together, please follow the Maximum power 

output limit of each zone of the V Power. 

 

The RJ45 plug that connects the 

V Inground

 unit to the V Power driver has the following wiring: 

 

 

PIN Color 

of 

wire 

RGB 

1 White/Orange 

Not 

used 

Orange 

Red LED +     

White/Green 

Blue LED + 

4 Blue 

Green 

LED 

5 White/Blue 

Not 

used 

Green 

Red LED - 

White/Brown 

Blue LED - 

Brown 

Green LED - 

RJ45  plug 

  (View facing pins) 

 

 

 

 

 

 

 

 

4.Change Beam Angle 

In this 

V Inground

 series, if you want to change the beam angle of fixture, you can change lens of the fixture 

refer to the photo below: 

 

 

5. Maintenance 

    - Clean the front transparent cover at least every 1-2 months. Use a moist, lint-free cloth. Never use alcohol 

or solvents!

 

 

Reviews: