background image

                                                                                                                           

VP-60/120

 

 

                                                                                                                          17- 

 

9.1 RJ45 Connection   

 

 

 

DMX Input, Output                                            LED module Input 

RJ45 Connector                         RJ45 Connector  

Front view of the Connector               Front view of the Connector 

                                               

 

 

Pin 1: 

Not connected   

Pin 5

: Not connected       

Pin 1:

 Red LED +       

Pin 5:

 Red LED - 

Pin 2:

 Not connected   

Pin 6:

 Data +                     

Pin 2:

 Green LED +   

Pin 6:

 Green LED - 

Pin 3:

 Not connected   

Pin 7:

 Data -                     

Pin 3:

 Blue LED +   

    Pin 7: 

Blue LED - 

Pin 4:

 Not connected   

Pin 8:

 GND                       

Pin 4:

 White LED +     

Pin 8: 

White LED - 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                                                                                           

VP-60/120

 

 

                                                                                                                          2- 

 

  1. Safety Introductions   

Please read the User Manual carefully as it includes important information regarding 

details of operation, maintenance and technical data. Keep this manual with unit for 

future consultation. 

 

WARNING

 

 

 

Avoiding any flammable liquids, water or metal objects enter into the unit. 

 If any liquid spill on the unit, disconnect the power supply immediately. 

 When serious operation problem happen, stop using the unit immediately and 

contact your local dealer for service. 

 Do not open the unit because there are no user serviceable parts inside. 

 Never try to repair the unit yourself. Repairs by unqualified people could cause 

damage or faulty operation. Please contact your nearest dealer for any service. 

 

CAUTION

 

 

 After removed the package, make sure the unit is not damaged in any way. Don’t 

use it with doubt and contact an authorized dealer. 

 Never use the unit under the excessive humidity and a temperature over 40

 Do not try to dismantle or modify the unit. 

 

2. Features   

 

7 Channel modes enables V Power to control passive lighting fixtures that fitted with 

different LED emitters. 

 

Comes with 16 built-in programs under Master/Slave mode. 3 user editable chases, 

each chase up to 50 (VP-60) or 42 VP-120

scenes. 

 

Under Manual mode, user can adjust each color’s intensity to get the best color 

mixing effects. 

 

White Balance setup-User can adjust the pre-set White Balance of the V Power. 

 

Smooth fade in/fade out effect. 

 

It can be controlled by the LED Remote Commander (LED-RC). 

 

LED display for easy navigation. 

Summary of Contents for V Power VP-120

Page 1: ...NO 008 V Power VP 60 VP 120 User Manual Please read the instructions carefully before use ...

Page 2: ...tion of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 ...

Page 3: ...d contact your local dealer for service Do not open the unit because there are no user serviceable parts inside Never try to repair the unit yourself Repairs by unqualified people could cause damage or faulty operation Please contact your nearest dealer for any service CAUTION After removed the package make sure the unit is not damaged in any way Don t use it with doubt and contact an authorized d...

Page 4: ... pin XLR plug and plug it in the DMX output of the last unit 3 Connect the unit together in a daisy chain by XLR plug from the output of the unit to the input of the next unit The cable can not branched or split to a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 4 The DMX output...

Page 5: ... any orientation and fixed by the two screws There are two mounting holes on the housing Ensure that installation place is enough ventilated V Power could control the LED fixtures such as V Aqua V Bar V Ceiling V Inground V Net V Wall and CW36 the VP 60 power output is 60 watt and the VP 120 power output is 120 watt ...

Page 6: ...utton and the display will blink Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will automatically return to the main functions without any change after idling one minute Back to the functions without any change press MENU button The main functions are shown below VP 60 120 14 ...

Page 7: ...o back to the previous function without any change press the MENU button Show Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the show 1 or or show 19 Once the show has been selected press the ENTER button and use DOWN and UP button to set fade time 0 255 0 256s 66847s and wait time 0 255 0 256s 66847s...

Page 8: ...e MENU button NOTE For VP 120 when you selected channel mode 5 or 6 you can set only color 1 for zone 1 2 for zone 2 and dimmer for every step When you selected channel mode 7 you can set only dimmer for every step Manual Mode Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the or red 1 for zone 1 2 fo...

Page 9: ...s shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to select the LED display ON or LED display OFF mode Once selected press ENTER button to setup or automatically return to the main functions without any change after idling one minute To go black to the previous function without any change press MENU button Fixture Hours Press the MENU button up to when ...

Page 10: ... OUT DMX Output RJ45 or 3 pin XLR socket 4 DMX IN DMX input RJ45 or 3 pin XLR socket 5 LED DC power signal output for linking LED fixtures 7 DMX Controller Using universal DMX controller to control the units you have to set DMX address from 1 to 512 so that the units can receive DMX signal Press the MENU button up to when the is showing on the display Pressing ENTER button and the display will bli...

Reviews: