N2K: Micro Drop cable
1 meter = 000-167-965
2 meter = 000-167-966
6 meter = 000-167-967
N2K: Micro Drop cable
6 meter
000-166-945
SC30 to FI5002 with FI505 instrument with NN3D
(15 or 30 meter antenna cable)
FI-5002 Junction Box
This is to supply voltage for
the N2K Bus. The minimum
voltage is 9 VDC and the
maximum is 16 VDC.
(13.6 VDC recommended)
1
2
3
4
5
Connect the wires to either of the
2 larger backbone connectors
inside the FI-5002.
Match the wire colors to the colors
shown on the backbone connector.
The Purple, Yellow and Green wires
in this cable are not used for this
connection. They need to be cut
back, isolated and taped so they
don’t short to any other wires and
cause equipment damage.
Appropriate fuse
or circuit breaker
Set only 1 Terminal Resistor
jumper to ON because the 15m
and 30m cables each have a
resistor built-in.
ON:
OFF:
N2K: SC30 Backbone cable
15 meter = 000-166-891
30 meter = 000-166-892
(One terminator resistor
is embedded in the SC30
connector end of these
optional cables)
Backbone connector
Connect to any of the 6
drop connection ports
inside the FI-5002. Match
the wire colors to the
colors shown on the drop
connector. (same as
shown for the backbone
connector)