4-6
8
IN ANALOG CAL
9
IN DIGITAL CAL
10
ACQUIRING CAL DATA
11
FILTER BEING CHANGED
12
EEPROM CODE ERROR - DEFAULT DATA LOADED
13
EEPROM READ ERROR
14
EEPROM WRITE ERROR
15
EEPROM DATA ERROR - FAULTED DATA REPLACED WITH DEFAULT DATA
ZERO LIMIT, FILTER, & MOTION SETIINGS
ZERO LIMIT (note on next page)
Setting
% of capacity
0
2
2
20
FILTER TUNE
AVERAGING
setting band
Response
setting averaging
(counts)
(counts)
0
OFF
OFF
1
1
4
0
1
2
2
8
1
2
3
4
16
2
4
4
8
32
3
8
5*
1
4
4
16
6*
2
8
5
32
7*
4
16
6
64
8*
8
32
7
128
*tune settings 5-8 double current averaging setting
MOTION
MOTION TIMER
setting counts
setting
time
0
OFF
0
0.8 sec
1
1
1
1.6 sec
2
2
2
32 sec
3
3
3
6.4 sec
If the count difference from conversion to conversion is greater than the motion setting, the motion status
bit is set to 1. Once the count difference from conversion to conversion returns to be equal to or less than
the motion setting, the motion bit remains set for the time selected for the Motion Timer.
Note 1: Zero limit settings are stored in EEPROM and are not lost if unit powers down. Filter and motion
settings are lost if unit powers down.
Note 2: counts refers to weight graduations. If weight graduations are 2 lb increments then presetting a
register to 2 would mean 4 lbs.