plug’n’dose AM
Operating and maintenance instructions
Copyright ©
Version 1.3
9 / 11
5.5
Shutting down
The unit is shut down in reverse order of setting up.
5.6
Operation
The control system is operated according to the control signals from the master controller
that are present at the connector (1) (see 5.4). The dosing quantity depends on the
connected dispenser.
6
Troubleshooting / Maintenance
Troubleshooting
Maintenance
The control system can be regarded as maintenance free. Do not use any aggressive
solvents or detergents to clean the unit, use a damp cloth only. Isolate from the power
supply before cleaning.
7
Specifications
Fault
Possible cause
Action
control system does not
operate, LED flashes, fault
signal is output (PIN 3).
Overcurrent shutdown
Clean the dispenser, if necessary
replace stator. See the operating
instructions for the dispenser.
Faulty motor
Dimensions (h x w x d)
142 x 85 x 50 mm
Mounting
4 holes / 5 mm, hole centres 130 x 48 mm
Weight
approx. 260 g
Supply
24 V DC
Mains adapter
230 V / 50 / 60 Hz
Consumption / rating
100 VA / 2.7 A
Operating conditions
+10°C to +40°C (Ta.), air pressure 1 bar
Storage conditions
dry / dust free -10 to +40°C