plug’n’dose AM
Operating and maintenance instructions
Version 1.3
Copyright ©
5.3
Important for signal definition
The amount of medium that is drawn back in by the suck-back must only be just enough
to prevent dripping.
If more is sucked in, air will enter the dispenser and the medium will emerge late at the
next dosing.
Caution:
If the suck-back is set higher than the dosing, the dispenser may be damaged
by running dry.
5.4
Starting up
• Ready the dispenser for operation in accordance with the supplied commissioning and
maintenance manual.
• Plug in the connector (3) of the dispenser (D)
• Connect (1) the cable of the master controller
1)
(B)
Notice:
The control system is only ready for operation when the dispenser is connected.
• Fill the dispenser with medium as directed in its operating and maintenance
instructions.
Caution:
The dispenser lead (connector 3) may only be connected and disconnected
when the power supply is isolated. The electronics in the drive motor could be damaged
if this precaution is not taken.
Only use the original connection and cable between Dispenser (D) and plug (3).
1)
after it has been connected to the master controller
Caution: Do not switch on
control system until medium has been delivered to it.
Otherwise there is a risk of
damage to the equipment.
Even a
short
test run can cause
irreparable damage to the stator.
Fig. 4 Connection schematic
Summary of Contents for preeflow plug'n'dose AM
Page 2: ...Printed 22 1 16 ...