• Uncouple the assembly aid and re-attach the star-shaped coupling (5) to the drive
unit (11).
• Insert the drive unit (11) into the dispenser housing (10). Ensure that the anti-rotation
lock (A) is positioned within the designated recess in the dispenser housing (10)
• Tighten both grub screws (14) and secure the end piece (27) with the screws (18).
Ensure that the anti-rotation lock (B) is positioned within the designated recess in the
end piece (27)
• Attach the air housing and precision dosing needle. Follow the steps in the reverse
order to the process shown in Fig. 5
5.2
Making the electrical connection
Connect the eco-CONTROL EC200 dosing control and eco-CONTROL SC1200 control
unit according to their respective operating and maintenance instructions.