2-1
Chapter 2: Customer Installation
707025-004
Chapter 2. Customer Installation
The 1199-C16/32 Multiplexer is designed to be customer installable. No special equipment
or tools are required to unpack or install the unit
Environmental Requirements
The following parameters must be adhered to for the proper operation of the 1199
Multiplexer.
Physical Statistics
1199-C16
1199-C32
Weight:
10.5 lb (4.8 Kg)
10.75 lb (4.9 Kg)
Height
3.37 in (8.56 cm)
3.37 in (8.56 cm)
Depth:
15.5 in (38.1 cm
15.5 in (38.1 cm)
Width
17.0 in (43.18 cm)
17.0 in (43.18 cm)
Power Consumption:
12. 25 W (typical)
24.5 W (typical)
Heat Dissipation:
42 BTU/hr
84 BTU/hr
Environmental Parameters
Clearance:
3 inches (7.62 cm) on each side of the unit for cooling
Temperature Range:
50° to 105°F (10 to 40.5C)
Relative Humidity:
8% to 80% (no condensation)
Maximum Wet Bulb:
80°F (26.7C)
Power:
90-132 VAC or 180-264 VAC at 47 to 63 Hz
Power Cable
For units operating at 100-120V: The power cable required for domestic units is a UL
listed, GSA certified, 18/3 AWG, type SVT or SJT, cable (15-foot [4.6-meter] maximum).
It is terminated on one end by a 125V, 15A grounding type attachment plug. It is terminated
at the other end by a 125V, lSA parallel blade, grounding type attachment plug.
For units operating at 200-240V: The power cable required for domestic units is a UL
listed, GSA certified, 18/3 AWG, type SVT or SJT, cable (15-foot [4.6-meter] maximum).
It is terminated on one end by a 250V, 15A grounding type attachment plug. It is terminated
at the other end by a
250V,
15A tandem blade, grounding type attachment plug.
The power cable required for international units is an 18/3 AWG, type SJT, cable (15-
foot [4.6-meter] maximum). It is terminated on one end by a 250V, 15A grounding type
attachment plug body. It is terminated at the other end by a 250V, ISA grounding type
cord connector. The cord set is marked HAR to signify appropriate safety approvals. The
socket outlet must be nearby and easily accessible, per LEC 950
Sec. 1.7.2.