VIROSMART VS-500 ULV User Manual Download Page 5

VS-500 ULV Device  

 

User Manual 

 

 
The most used and given with the device hardware are as below.  

 
 
 
 
 
 
 

 
 
 
 
 

2.1. Maintenance and Repair  

 
Repair  and  maintenance  of  the  VS-500  ULV  device  shall  be  performed  by  qualified  and  trained 
personnel.  If  you  own  the  ULV  device  and  need  your  device  to  be  repaired,  please  follow  the 
instructions  stated  in  this  manual.  Please  contact  Virosmart  technical  service  if  you  have  any 
problems  or  need  additional  parts,  equipment  and  testing  device  for  your  device.  Otherwise,  your 
device will be out of warranty if has a warranty coverage. 
 

2.2. Spare Parts   

 

Virosmart uses quality parts and raw materials for safe operation. Replace parts of the device that are 
worn and have completed their lifetime only with equivalent parts. Spare parts you may need during 
the warranty period are provided to you by  Virosmart. The names and numbers of original parts are 
indicated in this user manual. Use original parts for the safety of you and your device. Otherwise, note 
that your device will be out of warranty. 
 

2.3. Warranty Period and Conditions  
 

The  product  you  purchased  has 

a  year’s

 

warranty  against  any  disruption  or  dysfunction  within  the 

warranty.  Your  device  is  either  replaced  or  fixed  within  the  scope  of  warranty  for  manufacturing 
defects or faults of us. However, the following items are out of warranty. 
 

Not using the product in accordance with the instructions indicated in this user and 
maintenance manual 

Performing wrong maintenance and repair 

Occurrence of tearing or fraction on device resulting from impact or droppings  

Overutilization of device in a manner to affect the performance limit without a break 

Misuse 

– Wrong tool use during an incident or maintenance 

Faults occurred due to overheating depending on high contamination at air suction parts 

Wrong use of power 

The maintenance and repair to be made by unqualified and untrained personnel 

Use of spare part other than the original spare part 

It is not suggested to rent out the device, the faults to be occurred due to this reason is also 
out of warranty 

 
 
 
 
 

1. 

Spare Part 

 

Location 

Fluid Tank

 

For the fluid to be used in the 
implementation 

Power Plug 

Power plug used in countries  

Air Filter 

Spare of sponge air-suction filter 

Manual 

In the box 

2. SERVİICE SPARE PART AND WARRANTY CONDITIONS

 

Summary of Contents for VS-500 ULV

Page 1: ...ser Manual VS 500 ULV FOGGER USER MANUAL PLEASE READ BEFORE USE VIROSMART is a trading name of DARS Management Co Ltd Company Registrtion Number 11947523 Tel 44 1452 865255 Email sales virosmart co uk www virosmart co uk ...

Page 2: ...components turn off immediately at the wall socket and do not use Take to an authorised centre for repair Do not modify the machine this will void the warranty and compromise the safety of the machine Do not Inhale the fog mist when spraying The mircro droplets are quickly absorbed into the lungs Depending on the chemical being used this could result in serious injury or death Do not fog a flammab...

Page 3: ...ccordance with the related instructions VS 500 Overview Use the VS 500 for disinfection pest control odour control and plant protection The VS 500 works by expelling a fine almost invisible mist into the atmosphere which eventually settles on all surfaces including those impossible to reach by conventional methods The machine is compact lightweight and robust The large 5 litre tank and powerful 14...

Page 4: ...proach with flame to the solution store Please follow the instructions indicated in the user manual before starting maintaining or cleaning the device Wear a protective ear muffs while using Wear a protective glove while using Wear a suitable mask while the device is running to avoid poisoning Chemical used can be inflammable Symbols Labelling ...

Page 5: ... and Conditions The product you purchased has a year s warranty against any disruption or dysfunction within the warranty Your device is either replaced or fixed within the scope of warranty for manufacturing defects or faults of us However the following items are out of warranty Not using the product in accordance with the instructions indicated in this user and maintenance manual Performing wron...

Page 6: ... must be discharged with a tank cleaning after each use 4 1 Correct Use Operation The device shall only be used in below areas VS 500 ULV device is suitable for air surface disinfection and fighting against insecticide in accordance with the regulations determined by international authorities Follow criteria of fluid manufacturers while using VS 500 device Determine the amount to be used depending...

Page 7: ...ower current Operator is responsible for other people while using the device Do not use the device on people and animals in public areas Pay attention for no fluid to be poured on the device 4 3 Protective Equipment for your Safety While using the device always use protective clothing and equipment Wear a clothing in a way to cover your whole body head eyes and feet Furthermore a protective mask m...

Page 8: ...rvice Use 220 230 V 50 60 hz power 1 Chassis 2 ULV Cap 3 Tank 5 lt 10 lt 4 Tank Cap 5 On Off Button 6 Handle 7 Nozzle 8 Air Filter 9 M8 Bolt 10 Regulator 11 8 mm Hose 12 Suction Tube 13 Suction Seal Make sure all safety measures are taken before turning the device on TURNING ON 1 Before turning the device on take the necessary measures 2 Fill the fluid necessary for the implementation area to the ...

Page 9: ...g without PPE Be aware of your surroundings Watch out for animals which may be within your work area Be aware that noise is harmful to the environment Inquire about and respect possible local rest periods After each process add distilled water and start to device to rinse the lines To Avoid corrosion arting Stopping the de 1 Preparing Your Sanitisation Fluid Dilute Virosmart Virosol at 1 50 accord...

Page 10: ...ed as a dry fogging However in areas that are more sensitive such as offices where there is electronic equipment it is recommended to use a particle size of 12 microns or less When fogging areas such as stables or other outdoor environments a larger particle size can be used producing a wetter fog If precipitation occurs when sanitizing then the particle size is too large adjust as necessary to en...

Page 11: ...utton is off Turn on the power button Faulty engine Contact with the service Discontinuous Spray Air intake from suction line Check suction line and contact with service Not spraying fluid Regulator settings are off Make settings Fluid suction tube is plugged Clean the tube No fluid in tank Check fluid Implementation ended early Check settings Air filter is highly contaminated Replace with spare f...

Reviews: