Inst.300 Viron EVO Pool & Spa Pump V01_12
9
Startup:
When power is on, if the pump is in Off state, it will stand by.
When power is on, if the pump is in On state, it will auto-prime for 5 minutes at High Speed. While auto-priming the
factory preset Speed LED will be on and Speed 3 LED will keep flashing until auto-priming process is finished.
After auto-priming the pump will enter the factory preset Speed Level.
Fault LED: (in red)
When the pump is running, if warning condition is true, it will enter warning state. In warning state, the Fault LED
will flash and the pump itself will take over the speed control. The pump will return to normal operation in 3 minutes
after warning condition is gone.
Warning state can be cancelled by turning off the pump or cycling the power.
Warning conditions include: Over Temperature, Over Current, Under Voltage.
When the pump is running, if fault condition is true, it will enter fault state. In fault state, the Fault LED will be on
and the pump will stop by itself. The pump will NOT return to normal operation unless On/Off button is toggled or
power is cycled.
Fault state can be cancelled by turning off the pump or cycling the power.
Fault conditions include: Over Temperature, Over Current, Under Voltage, motor stuck.
OPERATION OF CONTROL PANEL
–
VIRON P600 EVO
The Viron P600 eVo incorporates an LCD backlit screen with the following features:
In built time clock:
Programmable for up to four timer periods each day
Timer periods can be disused and 1, 2, 3, or 4 periods selected
Different speed (low, medium, high) for each timer period
Displays actual RPM of motor and low, medium and high speed can be adjusted to suit your pool
Time clock and timer periods can be disabled if connected to an external time clock
Can be programmed by a compatible AstralPool remote control or chlorinator to operate at different
speeds during different times of the day
Enables the priming (start up) speed to be adjustable and the time of the start up speed to be changed
from 2 minutes up to 120 minutes
Viron P600 eVo Control Panel
0000