MICROCHIP REPLACEMENT
AND RESETING PROCEDURE
STEP 1
unscrew the 2 bolts at the bottom of control module
SALT CHLORINATOR SMC 20 / 30
Page 1: ...MICROCHIP REPLACEMENT AND RESETING PROCEDURE STEP 1 unscrew the 2 bolts at the bottom of control module SALT CHLORINATOR SMC 20 30 ...
Page 2: ...STEP 2 unplug the control board connecting cable ...
Page 3: ...STEP 3 ...
Page 4: ...STEP 4 remove the microchip and replace with new one please observe the correct position marked on the board ...
Page 5: ...l 3 Hold the ON MAX button and then plug the unit into the power supply Release the button when all green LED lights illuminates Unit will run for a 30 second in one direction polarity After that it stop for 5 second and start in reverse polarity The RESET Procedure is completed The production level can be adjusted accordingly to your needs by depressing the button MIN ...