Quick Reference Guide
27
Section 7
Quick Reference Guide
General Operation
When the system is operating, one of the following four displays
will be shown:
“TIME OF DAY/GPM”, “FLOW RATE”, “CAPACITY REMAINING”
or “DAYS TO A REGEN”. Pressing
NEXT
will toggle between the
three choices.
Manual Regeneration
Note:
For softeners, if brine tank does not contain salt, fill with salt and
wait at least two hours before regeneration. If you need to initiate a
manual regeneration, either immediately, or the same night at the pre
programmed time, for regeneration (typically 2:00 AM), complete the
following steps.
For Immediate Regeneration:
Press and hold
REGEN
until valve motor starts (typically 3 seconds).
For Regeneration the same night:
Press and release
REGEN
(notice that flashing “REGEN TODAY”
appears).
To Set Time of Day
In the event of a prolonged power outage, time of day flashes,
indicating that this needs to be reset. All other information will be
stored in memory no matter how long the power outage.
1
Accessed by pressing
SET
CLOCK
2
Adjust hours with
+
and
–
buttons, AM/PM toggles at 12
3
Press
NEXT
4
Adjust minutes with
+
and
–
buttons
5
Press
NEXT
6
Adjust current day with
+
and
–
buttons
7
Press
NEXT
to complete and return to normal operation
Error
If the display toggles between “ERROR”
and an error code (i.e. a number),
call a service technician and report the
error code.
Bypass
To shut off water to the system, position arrow handles as shown in the
bypass operation diagram below. If your valve doesn’t look like the
diagram below, contact your service technician for instructions on how
to shut off water.
Adjust Harness, Days Between Regeneration, Time of Regeneration and Alarm Buzzer:
For initial set-up or to make adjustments, please complete the following steps:
1
Accessed by pressing
NEXT
and
+
button simultaneously
2
Adjust hardness using
+
and
–
buttons
3
Press
NEXT
4
Adjust days between regenerations using
+
and
–
buttons
5
Press
NEXT
6
Adjust time of regeneration hour with
+
and
–
buttons, “AM/PM” toggles at 12:00.
7
Press
NEXT
8
Adjust time of regeneration minutes with
+
and
–
buttons
9
Press
NEXT
10
Turn alarm buzzer ON or OFF with
+
and
–
buttons
11
Press
NEXT
to complete and return to normal operation
for
REGEN TODAY AND TIME OF
DAY” WILL FLASH ALTERNATELY IF A
REGENERATION IS EXPECTED TONIGHT.
RETURN TO
GENERAL DISPLAY
NORMAL OPERATION
BYPASS OPERATION
RETURN TO
GENERAL DISPLAY