Troubleshooting
12
Section 4
Troubleshooting
Symptom
Possible Cause
Possible Solution
Timer does not display
“
TIME
OF
DAY
”
Transformer unplugged
•
Reconnect transformer
No power at outlet
•
Repair or use working outlet
Defective transformer
•
Replace transformer
Defective PC board
•
Replace PC board
Time does not display correct
time of day or “
TIME
OF
DAY
”
flashes
Outlet is on a switch
•
Used un-switched outlet
Power outage; transformer was unplugged from either wall
outlet or from PC board
•
Reset time of day and replace battery. Refer to
Defective PC board
•
Replace PC board
“
CHECK
SALT
” appears on
screen with audible alarm
Low salt in brine tank - alarm activated
•
Push any button on cover to stop alarm and add salt to
brine tank
Plugged injector and/or injector screen
•
Clean or replace injector and screen
Drain line plugged or restricted
•
Clean drain line restriction
Chlorine generator probes are dirty
•
Clean or replace chlorine generator
System drawing in air
•
Tighten fittings in brine system
System “short brining”
•
Clean brine line flow control, check for bridging or
hardened salt around brine well, increase brine refill time
Doesn’t display “SOFTENING”
when water is flowing
Bypass valve in bypass position
•
Put bypass in service position
Meter cable disconnected
•
Reconnect PC board
Restricted/stalled meter turbine
•
Remove meter and check for debris
Defective meter
•
Replace meter
Defective PC board
•
Replace PC board
Unit regenerates at wrong time
of day
Past power outage
•
Reset time of day
Incorrect time of day displayed
Time of regenerant set incorrectly
•
Reset time of regeneration
Control set at “
ON
0
”
•
Check with regeneration time option in programming
Control set at “
NORMAL
+ on
0
”
5
• RAPID
RINSE
POSITION
:
Chlorine generator is off. Raw
water enters control head and
flows down through the
Zeolite mineral, rinsing any
excess brine to drain.
6
• BRINE
TANK
FILL
POSITION
: Water enters
control head to self clean
injector while flowing back to
refill the brine tank. Unit will
deliver soft water in this
position.