background image

USER MANUAL

ENGLISH

The humidity must be between 30% and 95%.

Do not use the machine as a means of transport.

In case of fire, use a powder fire extinguisher, not a water one.

Do not tamper with the machine safety guards and follow the ordinary maintenance instructions scrupulously.

Do not allow any object to enter into the openings. Do not use the machine if the openings are clogged. Always keep 
the openings free from dust, hairs and any other foreign material which could reduce the air flow.

Do not remove or modify the plates affixed to the machine.

If the machine is used according to the instructions, the vibrations are not dangerous. The machine vibration level is 
less than 2.5 m/s

2

(98/37/EEC-EN 1033/1995).

This machine cannot be used on roads or public streets.

In case of machine malfunctions, ensure that these are not due to lack of maintenance. If necessary, request 
assistance from the authorised personnel or from an authorised Service Center.

If the machine

does not work properly

is damaged

has water or foam leaks

has been left outdoors exposed to bad weather conditions

is wet or has been dropped into water

turn it off immediately and contact Viper Service Center or a qualified technician.

If parts must be replaced, require ORIGINAL spare parts from an Authorised Dealer or Retailer.

To ensure machine proper and safe operation, the scheduled maintenance shown in the relevant chapter of this
Manual, must be performed by the authorised personnel or by an authorised Service Center.

Carefully read all the instructions before performing any maintenance/repair procedure.

Do not wash the machine with direct or pressurised water jets, or with corrosive substances.

The machine must be disposed of properly, because of the presence of toxic-harmful materials (batteries, electrical 
components, etc.), which are subject to standards that require disposal in special centres (see Scrapping chapter).

14019E (1) 2010-12 A

DF-100A-EU

5

Summary of Contents for DF-100A-EU

Page 1: ...QJ IUDQ DLV 1RWLFH G XWLOLVDWLRQ QHGHUODQGV HEUXLNVDDQZLM LQJ LWDOLDQR VWUX LRQL VXOO XVR HVSD RO QVWUXFFLRQHV GH PDQHMR SRUWXJX V QVWUX HV GH RSHUD R RPSDQ LQIRUPDWLRQ ZZZ YLSHUFOHDQLQJ HX LQIR HX YL...

Page 2: ...ENCE MANUALS 2 SPARE PARTS AND MAINTENANCE 2 CHANGES AND IMPROVEMENTS 3 OPERATION CAPABILITIES 3 CONVENTIONS 3 UNPACKING DELIVERY 3 SAFETY 3 SYMBOLS 3 GENERAL INSTRUCTIONS 4 MACHINE DESCRIPTION 6 MACH...

Page 3: ...ids and other substances that can cause damage to it DECLARATION OF CONFORMITY The declaration of conformity supplied with the machine certifies the machine conformity with the law in force NOTE Two c...

Page 4: ...with the following features 1 Technical documents Form generation User Manual Form generation Spare Parts List SAFETY The following symbols indicate potentially dangerous situations Always read this...

Page 5: ...cracks cuts etc If the power supply cable is damaged replace it immediately To avoid any risk if the power supply cable is damaged contact Viper Service Center or a qualified technician Do not pull or...

Page 6: ...request assistance from the authorised personnel or from an authorised Service Center If the machine does not work properly is damaged has water or foam leaks has been left outdoors exposed to bad wea...

Page 7: ...utlet 2 Body Foam Generator 3 Knob Foam Filter 4 Knob Foam Adjusting 5 Solution Inlet 6 Bracket Foam Generator MNTG 7 Power Supply Cord 8 Knob Filter 9 Serial Number Label 10 Hint 11 Mesh Inlet Filter...

Page 8: ...TA Model DF 100A EU Voltage 230V Frequency 50HZ Power 150W Current 1 0 A IP Class IP 44 Volume of solution tank 6 Liters Sound pressure level at workstation 68dB A Weight 6kg Length of Power cord 1 0m...

Page 9: ...ENGLISH USER MANUAL WIRING DIAGRAM FOR DF 100A EU 8 DF 100A EU 14019E 1 2010 12 A...

Page 10: ...Foam Outlet Hose F to the fitting on the polisher b4 Connect the Power Supply Cord G to the socket on the polisher rear handle housing 2 Solution Mix the Viper 508 carpet cleaner with water Ratio 1 1...

Page 11: ...bolts and replace as necessary 3 Foam filter 12 Inlet Filter 11 and Solution Filter 13 need to be cleaned periodically 4 Please check up the filters if foam volume is less than normal 5 Please empty...

Reviews: