Manual VIPA System 300S SPEED7 

Chapter 2   Hardware description and deployment 

HB140E - PS - RE_307-1FB70 - Rev. 13/43 

 

2-1 

Chapter 2  

Hardware description and deployment 

 

Here the hardware structure and the deployment of the Co Power Supply 
together with the CPU 317S is described. 

The technical data are at the end of the chapter.  

 

 

Topic     

Page 

Chapter 2

 

Hardware description and deployment ......................... 2-1

 

Safety Information for Users................................................................. 2-2

 

Properties............................................................................................. 2-3

 

Structure .............................................................................................. 2-4

 

Technical data...................................................................................... 2-5

 

 

 

 

 

Overview 

Content 

Summary of Contents for PS 307S_Co

Page 1: ...VIPA System 300S SPEED7 PS 307 1FB70 Manual HB140E_PS RE_307 1FB70 Rev 13 43 October 2013...

Page 2: ...sions Conformity is indicated by the CE marking affixed to the product Conformity Information For more information regarding CE marking and Declaration of Conformity DoC please contact your local VIPA...

Page 3: ...ry information for commissioning and operation About this manual 1 Safety information 2 Chapter 1 Assembly and installation guidelines 1 1 Overview 1 2 Installation dimensions 1 3 Assembly SPEED Bus 1...

Page 4: ...Contents Manual VIPA System 300S SPEED7 2 HB140E PS RE_307 1FB70 Rev 13 43...

Page 5: ...Every chapter provides a self contained description of a specific topic The following guides are available in the manual an overall table of contents at the beginning of the manual an overview of the...

Page 6: ...plosive environments EX zone The manual must be available to all personnel in the project design department installation department commissioning operation The following conditions must be met before...

Page 7: ...his chapter you will find all information required for the installation and the cabling of a PLC system with the components of the System 300 and the Co Power Supply Topic Page Chapter 1 Assembly and...

Page 8: ...ackplane bus connector Before installing the modules you have to clip the backplane bus connector to the module from the backside A backplane bus connector is scope of delivery of a peripheral module...

Page 9: ...Assembly and installation guidelines HB140E PS RE_307 1FB70 Rev 13 43 1 3 Installation dimensions 1tier width WxHxD in mm 40 x 125 x 120 65mm 40mm 122 mm 125 mm 125mm 120mm 175mm Dimensions basic encl...

Page 10: ...ove and 40mm below the profile rail Please look for a low impedance connection between profile rail and background Connect the profile rail with the protected earth conductor The minimum cross section...

Page 11: ...ation bolt of the profile rail Fix the power supply by screwing SLOT1 DCDC CPU SLOT2 Modules PS 307S_Co To connect the SPEED Bus modules plug it between the triangular positioning helps to a plug in l...

Page 12: ...n Fix the CPU by screwing SLOT1 DCDC CPU SLOT2 Repeat this procedure with the peripheral modules by clicking a backplane bus coupler stick the module right from the modules you ve already fixed click...

Page 13: ...0 08mm2 to 2 5mm 2 You can use flexible wires without end case as well as stiff wires You fix the conductors to the CageClamps like this 1 2 1 Rectangular opening for screwdriver 2 Round opening for w...

Page 14: ...erencing the environment All System 300 components are developed for the deployment in hard industrial environments and fulfill high demands on the EMC Nevertheless you should project an EMC planning...

Page 15: ...d isolated for details see below Analog lines must be laid isolated When transmitting signals with small amplitudes the one sided laying of the isolation may be favorable Lay the line isolation extens...

Page 16: ...lay the isolation one sided Then you only achieve the absorption of the lower frequencies A one sided isolation connection may be convenient if the conduction of a potential compensating line is not p...

Page 17: ...al installation EN 61131 2 0 60 C Vertical installation EN 61131 2 0 60 C Air humidity EN 60068 2 30 RH1 without condensation rel humidity 10 95 Pollution EN 61131 2 Degree of pollution 2 Mechanical O...

Page 18: ...Chapter 1 Assembly and installation guidelines Manual VIPA System 300S SPEED7 1 12 HB140E PS RE_307 1FB70 Rev 13 43...

Page 19: ...ption and deployment Here the hardware structure and the deployment of the Co Power Supply together with the CPU 317S is described The technical data are at the end of the chapter Topic Page Chapter 2...

Page 20: ...perable or unusable Modules damaged in this way are normally not immediately recognized The according error may occur only after a while of operation Modules that have been damaged by electrostatic di...

Page 21: ...labeled with Slot1 DCDC The Co Power Supply may only be operated together with the CPU 317S As soon as the CPU 317S is power supplied the Co Power Supply starts automatically Operates exclusive toget...

Page 22: ...y by front side SF red Error Co Power Supply inactive On If missing power supply of the CPU 317S if wrong slot respectively if not mounted at SPEED Bus As soon as the DC 24V input voltage is present a...

Page 23: ...5 A Power supply parallel switchable Protect type short circuit electr overload over temperature IP20 Ripple of output voltage max BW 20 MHz 150 mV Efficiency typ 90 Power loss typ 6 W Status informa...

Page 24: ...Chapter 2 Hardware description and deployment Manual VIPA System 300S SPEED7 2 6 HB140E PS RE_307 1FB70 Rev 13 43...