9
Connection / Connectors for Analog Signals
S
O
U
R
C
E
1
2
3
HOT
COLD
SHIELD
X
Balanced Cable (Signal) to (Transformer) Balanced Input
BALANCED INCOMING SIGNAL
XLR MALE PLUG
Shield = Signal Ground = Pin 1
Hot / + Phase = Pin 2
Cold / - Phase = Pin 3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
to earth potential (PE) when plugged into the
corresponding socket of the case !
ANALOG SIGNALS
ANALOG SIGNALS
S
O
U
R
CE
1
2
3
HOT
GND
SHIELD
X
Unbalanced Cable (Signal) to (Transformer) Balanced Input
BALANCED INCOMING SIGNAL
XLR MALE PLUG
Shield = Signal Ground = Pin 1
Hot / Signal = Pin 2
Cold / Ground = Pin 3
The case of the connector should not be wired
to the shield of the cable. The connector is routed
to earth potential (PE) when plugged into the
corresponding socket of the case !
ANALOG SIGNALS
?
2-wire cable should be prefered !!
zum
Kopfhörer
6.3 mm (1/4”) Phone Jack ( ip - ing - leeve Connector)
T
R
S
Tip = left Channel
Ring = right Channel
Sleeve = Ground