14
THE ANALOG OUTPUTS
The analog outputs are situated on the rear panel, fitted with electroni-
cally balanced XLR terminals, as well as cinch sockets.
Both outputs may be used simultaneously !!
Polarity of the XLR terminals complies with AES 14-1992:
1 = ground, 2 = (+) in phase, 3 = (-) out of phase.
Source impedance of all analog outputs is significantly lower than 1
(one) ohm !
NOTE:
When connecting unbalanced lines to the balanced outputs, pin 3 must
not be bridged but left unused. In this case the resulting output level will
be 6 dB less.
THE POWER SWITCH
The unit is activated by means of the power switch. Power-on status is
indicated by the blue LED below.
INPUT SELECTION
By pressing the “INPUT SELECT“ button, the inputs USB > BALanced >
COAXial > OPTO can be selected in clockwise order.
If a valid signal is present at the corresponding input, the blue "lock"
LED will come up. Unused inputs or such with an invalid digital signal
present are indicated by the red “MUTE ON / ERROR“ light.