4. Setting an IP Address Using a Web Browser
•
Connect the Ethernet cable between the Arctic device LAN port and your
computer.
•
Configure your computer to use the same IP address space as the Arctic device
(for example, your computer IP could be 10.10.10.11 with netmask 255.0.0.0).
Check with ping command.
•
Connect to the Arctic device using the web browser. The default address of the
Arctic is
https://10.10.10.10/
. Please make sure to use
https
and not http (see
figure 3).
•
Login to the device, the username is
viola-adm
and the default password is
violam2m
Note! It is highly recommended that the default password is
changed before the product is connected to the public cellular network.
Figure 3.
Browser https example