GETTING STARTED AND INITIATING A DISINFECTION CYCLE  

1.

 

After completing the setup instructions, the Vioguard Cubby / Cubby+ is ready for use.  

2.

 

Open the front door. 

3.

 

Pull out the tray. 

4.

 

Place your item on the tray. 

a.

 

For the Cubby, if you desire to use the pass-through USB port, plug your USB cable into the 
connector port located to the rear left of the tray.  Connect the unit via a USB A-B cable to a 
computer or power supply depending on the device needs. 

b.

 

Please note that the Cubby+ does not have USB pass-through and the rear USB port is non-
functional. 

5.

 

Push the tray back into the unit. 

6.

 

Close the door to begin the disinfection process. 

7.

 

The LCD will indicate the start of the cleaning process. 

8.

 

Please refer to the LCD Panel Indications for more information regarding the Disinfection Cycles. 

9.

 

Please note that there is a 1-second delay in startup to prevent surges to the power supply if the 
door is opened and closed rapidly.  The door needs to be open for at least 1 second for the unit to 
begin the disinfection cycle. 

 

2. 

  3.

 

4. 

  6.

 

 

Summary of Contents for Cubby

Page 1: ...Vioguard Cubby Cubby User Manual Trademark Vioguard Inc 110 00257 01 Rev A ...

Page 2: ...roperly set up use and care for the Cubby Cubby can increase the risk of serious injury or death or damage to the unit Read this manual for important safety and health information Keep this manual for future reference For a replacement user manual or to see the most updated version go to vioguard com manuals or contact Vioguard customer support at 425 318 7900 Read the complete manual for importan...

Page 3: ...g Started and Initiating a Disinfection Cycle 6 LCD Panel Indications 7 Cleaning Procedures 8 Limited One Year Warranty 9 No Other Warranties 10 Warranty Service 11 How to Obtain Warranty Service 12 Changes to Warranty Service 13 Limitations on Warranty Service 14 Limitation of Remedies 15 Limitation of Liability ...

Page 4: ...ing disinfection cycles Includes Enclosure with shelf AC power cable user manual Disinfection Cycle Time 20 to 120 seconds depending on dosage Product Warnings Ultraviolet UV C Radiation Hazard Any exposure to the UV C will cause significant eye damage and may cause skin damage If direct light from the UV C lamps inside the enclosure is visible remove power and stop using immediately and contact V...

Page 5: ... for indoor use only 7 Do not alter the construction or design Do not remove safety labels or devices 8 Do not use equipment for other than its intended purpose as described in the equipment manual 9 On equipment with blowers keep inlet and outlet vents clean and clear of objects 10 Germicidal ultraviolet rays may break down plastic rubber or other non metallic materials can fade colors and can be...

Page 6: ... Unpack the main Cubby Cubby Unit 4 Unpack the provided AC power cord 5 Plug the AC power cord into the back panel AC power socket of the unit and then plug the other end into an AC power source The unit will power on automatically 6 The enclosure of the Vioguard Cubby Cubby is designed to support up to 50lbs 7 Wait for the LCD to illuminate and sequence through its startup icons 8 The unit will b...

Page 7: ...upply depending on the device needs b Please note that the Cubby does not have USB pass through and the rear USB port is non functional 5 Push the tray back into the unit 6 Close the door to begin the disinfection process 7 The LCD will indicate the start of the cleaning process 8 Please refer to the LCD Panel Indications for more information regarding the Disinfection Cycles 9 Please note that th...

Page 8: ... Clean Cycle Averages a total time of 90 180 seconds from start of process at door closure Once the Deep Clean Cycle is completed you can safely remove the device from the chamber at your discretion UVC lights are on during the Deep Clean Cycle but will turn off upon completion 4 Status Bar The Status Bar tracks the UVC Disinfecting Cycle The bar will fill from left to right with a designation lin...

Page 9: ...loth or allow to air dry 4 Reconnect the Cubby Cubby to A C power DO NOT pour any liquid cleaner or disinfectant directly on any surface of the Vioguard Cubby Cubby Recommended Cleaners Disinfectants Chlorine based max 10 solution alcohol based quaternary ammonium soap and warm water Note Use manufacturers recommendations for concentrations DO NOT use the following Petroleum based cleaning fluids s...

Page 10: ...than routine maintenance done by or in behalf of the user as described in this manual or modified by anyone other than Vioguard or any Vioguard authorized third party without Vioguard s prior written approval or whose serial number is defaced altered or removed NO OTHER WARRANTIES The above warranty is exclusive and in lieu of all other representations or warranties whether written or oral express...

Page 11: ... Repairs have a 90 day warranty If the Vioguard Cubby Cubby sent in is still under its original warranty the new warranty is 90 days or to the end of the original one year warranty whichever is longer HOW TO OBTAIN WARRANTY SERVICE To obtain Warranty Service you must do the following 1 Promptly notify Vioguard 1 425 318 7900 or info vioguard com upon discovery of the product s failure to perform a...

Page 12: ...aw or in equity shall in no event exceed the total contract price for any product with respect to which losses or damage occurred and shall not exceed the price you paid for the Vioguard Cubby Cubby No consequential damages except where prohibited by law in no event including late delivery or failure to deliver shall Vioguard be liable to anyone for special collateral indirect exemplary incidental...

Reviews:

Related manuals for Cubby