SP-2000/X-Y
Operation
User Manual
2-5
2.
Press the Standby/Charge (yellow) button and hold it until the relay latches
and the yellow light stays on. If the external power supply is connected, it
is now charging the batteries. The green Battery Charge LED will illumi-
nate confirming that DC power is reaching the pedestal. The “voltmeter” to
the left of the Battery Charge LED indicates the battery voltage.
3.
Press the Run (green) button to power up the pedestal.
4.
The column and the three wheels will initialize. You will see the direction
indicators on the wheels rotate one by one as they initialize. Do not attempt
to drive the pedestal until initialization is complete.
5.
Once the pedestal is powered up and initialized, turn on the head.
Powering Down
Always power down the head before the pedestal.
The pedestal can be powered down to Standby/Charge mode or turned off com-
pletely in Stop mode. Or, in an emergency, use any one of the three Emergency
STOP Switches - see next section.
Standby/Charge
In normal operation, if the pedestal will be left unattended for a long period of
time (overnight for example), press Standby/Charge to power down the elec-
tronics but leave the batteries charging.
Stop
Press Stop to power down the pedestal completely.
Summary of Contents for AutoCam SP-2000/X-Y
Page 10: ...Table Of Contents x This page left blank intentionally ...
Page 11: ...User Manual 1 1 1 Safety Introduction ...
Page 21: ...SP 2000 X Y Safety Introduction User Manual 1 11 This page left blank intentionally ...
Page 28: ...SP 2000 X Y Safety Introduction 1 18 User Manual This page left blank intentionally ...
Page 29: ...User Manual 2 1 2 Operation ...
Page 40: ...SP 2000 X Y Operation 2 12 User Manual This page left blank intentionally ...
Page 41: ...User Manual 3 1 3 Installation ...
Page 57: ...SP 2000 X Y Installation User Manual 3 17 This page left blank intentionally ...
Page 63: ...SP 2000 X Y Installation User Manual 3 23 This page left blank intentionally ...
Page 67: ...User Manual 4 1 4 Maintenance And Repair ...
Page 71: ...SP 2000 X Y Maintenance And Repair User Manual 4 5 This page left blank intentionally ...
Page 79: ...SP 2000 X Y Maintenance And Repair User Manual 4 13 This page left blank intentionally ...
Page 81: ...SP 2000 X Y Maintenance And Repair User Manual 4 15 North Sensors West Sensors ...
Page 85: ...SP 2000 X Y Maintenance And Repair User Manual 4 19 This page left blank intentionally ...
Page 91: ...SP 2000 X Y Maintenance And Repair User Manual 4 25 This page left blank intentionally ...
Page 95: ...SP 2000 X Y Maintenance And Repair User Manual 4 29 This page left blank intentionally ...
Page 106: ...SP 2000 X Y Index IV This page left blank intentionally ...