Fault finding
Fault
Possible cause
Remedy
The appliance is not
working.
Power failure; the fuse is blown;
the appliance is not plugged in
correctly.
Check that power is connected.
Reset the fuse.
Water collects in
the bottom of the
cabinet.
The defrost water pipe is
blocked.
Clean the defrost water channel
and the drain hole on the rear
wall of the cabinet.
Vibration or
bothersome noise.
The appliance is not level.
The appliance is resting against
other kitchen elements.
Containers or bottles inside the
cabinet are rattling against one
another.
Level the appliance using a spirit
level.
Move the appliance away
from the kitchen elements or
appliances it is in contact with.
Move containers and/or bottles
apart.
Compressor runs
continuously.
High room temperature.
Ensure adequate ventilation.
Error code (E1)
Top sensor not working.
The appliance continues to run
as a single zone.
Call service agent to repair
sensor.
Error code (E2)
Defrost sensor not working.
Call service agent to repair
sensor.
Error code (E3)
Bottom sensor not working. The
appliance continues to run as a
single zone.
Call service agent to repair
sensor.
19