4
901302 REV E 07/16/19, SLIMLINE COOL PG 4 OF 11
IMPORTANT NOTICE-PLEASE READ
FOR MAXIMUM SYSTEM PERFORMANCE VINTAGE AIR RECOMMENDS THE FOLLOWING:
LUBRICANT CAPACITIES:
134a SYSTEM
CHARGE WITH 1.8 lbs.
(1lbs. 12ozs) OF REFRIGERANT
NEW COMPRESSOR - NO ADDITIONAL OIL NEEDED
USED COMPRESSOR - CONSULT VINTAGE AIR
SERVICE INFO:
SAFETY SWITCHES:
ATTENTION: SYSTEM COMPONENTS: THE COMPRESSOR, EVAPORATOR, CONDENSER & DRIER ARE CAPPED.
CAPS MAY BE UNDER PRESSURE WITH DRY NITROGEN; BE CAREFUL REMOVING CAPS. DO NOT REMOVE CAPS
PRIOR TO INSTALLATION. REMOVING CAPS PRIOR TO INSTALLATION WILL CAUSE COMPONENTS TO COLLECT
MOISTURE AND LEAD TO PREMATURE FAILURE AND REDUCED PERFORMANCE.
EVACUATE THE SYSTEM FOR 35-45 MINUTES WITH SYSTEM COMPONENTS (DRIER, COMPRESSOR, EVAPORATOR
AND CONDENSER) AT A TEMPERATURE OF AT LEAST 85° F. ON A COOL DAY THE COMPONENTS CAN BE HEATED
WITH A HEAT GUN OR BY RUNNING THE ENGINE WITH THE HEATER ON BEFORE EVACUATING. LEAK CHECK
AND CHARGE TO SPECIFICATIONS.
TTH
HIISS K
KIITT D
DO
OEESS N
NO
OTT C
CO
ON
NTTA
AIIN
N H
HEEA
ATTEERR H
HO
OSSEE.. YYO
OU
U M
MU
USSTT PPU
URRC
CH
HA
ASSEE 88 FFEEEETT O
OFF 55//88”” D
DIIA
A..
H
HEEA
ATTEERR H
HO
OSSEE FFRRO
OM
M VVIIN
NTTA
AG
GEE A
AIIRR((3311880000--VVU
UD
D)) O
ORR FFRRO
OM
M YYO
OU
U R LLO
OC
CA
ALL PPA
ARRTTSS RREETTA
AIILLEERR.
VINTAGE AIR SYSTEMS ARE DESIGNED TO OPERATE WITH R134a REFRIGERANT
ONLY! USE OF ANY OTHER REFRIGERANTS IS A FIRE HAZARD AND COULD
DAMAGE EITHER YOUR AIR CONDITIONING SYSTEM OR YOUR VEHICLE.
USE OF ANY OTHER REFRIGERANTS WILL VOID ALL WARRANTIES OF
THE AIR CONDITIONING SYSTEM AND COMPONENTS. USE OF THE PROPER
TYPE AND AMOUNT OF REFRIGERANT IS CRITICAL TO PROPER SYSTEM
OPERATION. VINTAGE AIR RECOMMENDS OUR SYSTEMS BE CHARGED BY
WEIGHT WITH A QUALITY CHARGING STATION OR SCALE.
REFRIGERANT CAPACITIES FOR VINTAGE AIR SYSTEMS
(FOR OTHER SYSTEMS, CONSULT MANUFACTURER GUIDELINES)
A COMPRESSOR SAFETY SWITCH MUST BE INSTALLED ON EVERY A/C SYSTEM. A BINARY SWITCH
DISENGAGES THE COMPRESSOR CLUTCH IN CASES OF EXTREME LOW PRESSURE (REFRIGERANT LOSS) OR
EXCESSIVELY HIGH HEAD PRESSURE (406 PSI) TO PREVENT COMPRESSOR DAMAGE OR HOSE RUPTURE. A
TRINARY SWITCH COMBINES HI/LO PRESSURE PROTECTION WITH AN ELECTRIC FAN OPERATION SIGNAL AT
254 PSI. COMPRESSOR SAFETY SWITCHES ARE EXTREMELY IMPORTANT SINCE AN A/C SYSTEM RELIES ON
REFRIGERANT TO CARRY LUBRICATION THROUGH THE SYSTEM.