background image

Operational instructions

1. Lift Column

Press the    button or    button to control the lift column up or down    Press the button to control 

up of the lifting column, you can see the height (displayed number) on the screen; press the 

button to control the down of the lifting column, you can see the height (displayed number) on 

the screen.

2. Set memory height

Press(              ) button for 2 seconds, set the current height to the memory height, When 

ashing 

display "H1~H4"2 seconds, after 2 seconds display real-time height.

3. call memory height

Press the number button (               ) can call its corresponding height, lift column will automatically 

run to the right position.

4. stroke reset

 "E10

E20" alarm state or running to the lowest height position, press the button    3 seconds, 

after the display (       Reset) is released, the lifting column starts to run down to the bottom of 

the frame and rebound to a certain height, the reset is completed to display the lowest height.

5. protection and alarm

1.Block Protection: Display "E02." During the movement of the desk top vibration, collision or 

tilt desktop, which will alarm and immediately stop, reverse motion set the distance after 

automatic release, or in the reverse run press any key to stop and release. should be checked 

and ensured that the table does not vibrate substantially during operation, hit an obstacle or 

occur a tilt re-run.

2.Overheating protection: Display "Hot ." Continuous operating may initiate this protection 

and should be recharged or waited for at least 18 minutes before use.

3.Motor abnormal protection: Display "E10." Should be power off, re-check and ensure that 

the connection of the motor to the controller is reliable and then reconnect.

4.Overload protection: Display "E20." This alarm should be removed from the desk top when 

it’s operating up; if this alarm occurs when it’s operating down, cut off the power and the 

heavy objects should be removed, and the power should be re-charged.

5.Under-voltage protection: Display "E31." Should be power off, recheck and make sure the 

connection between the power supply and the handset is reliable, then connect the power.

6.Over-voltage protection: Display "E32." Should be power off, recheck and make sure the 

connection between the power supply and the handset is reliable, then connect the power.